R410a pressures at 90 degrees

At 90 degrees Fahrenheit or less, the low-side should be near 30 PSI. There is a problem if the pressure is too much lower or higher. ... At these operating conditions, the discharge pressure is around 400 Psig. R-410A operates at 50 to 70% higher pressures than the R-22. What is the 134a refrigerant’s suction pressure?

R410a pressures at 90 degrees. R410A is a blend of two hydrofluorocarbon (HFC) refrigerants: R32 and R125. These two components work together to create a refrigerant with excellent thermodynamic properties. R32 provides high energy efficiency, while R125 contributes to the stability and heat transfer performance of R410A. When it comes to the chemical composition of R410A ...

A 90-degree angle has an internal angle equivalent to 90 degrees and forms a perfect L shape. It is also known as a right angle. Ninety-degree angles are found in both geometry and...

R22 boiling point: -40.8 degree Celsius at atmospheric pressure (sea level or 1 ATM) R22 density: 3.66 g/cm 3, in gas form - this is a colorless gas. R22 molar mass: 86.47 g/mol. R22 gas cylinder identification: light green. R2 status: no longer in active use, replaced with R458A. Forane 410A Pressure Temperature Chart. Saturation Pressure-Temperature Data for R-410A (psig)*.In this article, we will discuss an HVAC unit’s refrigerant pressure on both the high side and the low-pressure side while the system runs. It is important to know the range of these pressures in order to understand why and how charging and recovery are performed.What is the normal operating temperature for 410A? Normal operating temperatures for R-410A systems typically range between 35 to 60 degrees Fahrenheit (1.7 to 15.6°C) for the evaporator coil temperature and 90 to 135 degrees Fahrenheit (32.2 to 57.2°C) for the condenser coil temperature.Pseudo-Pure Fluid Equations of State for the Refrigerant Blends R-410A, R-404A, R-507A, and R-407C. ... Maximum pressure [Pa] 50000000.0. Triple point. Triple point temperature [K] 200.0. Triple point pressure [Pa] 29160.33537476026. Critical point. Critical point temperature [K] 344.494.Aug 14, 2023 · One key factor that plays a pivotal role in ensuring efficient cooling on such hot days is the careful management of 410a refrigerant pressures. In this expert guide, we delve into the complexities of balancing 410a pressures during the sweltering heat of a 95 degree day. As temperatures soar, HVAC systems are put to the test, and maintaining ... This is where our friend R-410A came into play. New machines from 2010 and onwards were banned from using R-22. Instead, they were outfitted with R-410A. If you would like to read more about R-410A refrigerant please have a look at our Puron fact sheet. R-410A PT Chart. Let’s take a look at our pressure table for R-410A Puron.

Refrigerant Pressure vs. Temperature Charts for Pioneer Split Systems (R410a) Charts provided herein are for indicative purposes only. Various other conditions may effect the …I'm currently being humbled by a 3 year old, 5 ton 410a system. It was installed on a 100k BTU furnace that is over 25 years old. VERY shitty install. Symptom was not cooling enough. Put my gauges on and got the following: 180 suction line pressure 320 discharge. 10 degree temp split. No temp difference across the filter drier.Nov 16, 2020 · The low-side should be near 30 PSI at 90 degrees Fahrenheit or less. Pressure that is too much lower or higher shows there is a problem. On a properly working system, high-side pressure will be about twice the ambient temperature, plus 50 PSI. At 90 degrees Fahrenheit or less, the low-side should be near 30 PSI. There is a problem if the pressure is too much lower or higher. ... At these operating conditions, the discharge pressure is around 400 Psig. R-410A operates at 50 to 70% higher pressures than the R-22. What is the 134a refrigerant’s suction pressure?Quick Example: Let’s say that we have a 3-ton 16 SEER AC are using R-410A refrigerant and want to calculate R-410A superheat. With low side blue gauge on the suction line service port, we measured 130 psi pressure that correlates (according to R-410A PT chart) to about 45°F. The clamp-on thermometer shows that the saturated refrigerant ...

27.4 90.8 207.7. 2.7. 28.3 92.6 210.8. 4.8. 25.7 87.4 201.8. 4.1. 26.5 89.1 204.7. Temp (°F) Pressure Temp (psig) (°C) 5.4. 24.9 85.7 198.8 Saturation Pressure-Temperature Data for R22 (psig)* Temp (°F) Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Created Date:Digital Fieldpiece Gauges: https://amzn.to/2LFjNnKR410A Equipment: https://amzn.to/2xv6AG5My Favorite Tool: https://amzn.to/3NIFJuOTools We …In this article, we will discuss an HVAC unit’s refrigerant pressure on both the high side and the low-pressure side while the system runs. It is important to know the range of these pressures in order to understand why and how charging and recovery are performed.The condenser comes charged with 15 feet of 410A. My install has 40 feet of 3/8" and 7/8" line total --- leaving 25 feet needing additional refrigerant. (Goodman suggest adding .6 oz per foot of liquid line) but that seems to be high. At the present time I am setting at 308 (High Side and 143 Low Side with no charge added beyond the 15 foot ...From the PT chart, we can read that the pressure of liquid 448a on a 90-degree day is 208.4 psig. Similarly, we can see that the vapor pressure of 448a on a 90-degree is 181.2 psig. Example 7: What Are 448a Pressures On A 95-Degree Day? From the PT chart, we can read that the pressure of liquid 448a on a 95-degree day is 224.4 psig.

Marvel metal cards 1995.

Step 1. A cascade system with one refrigeration cycle operating with R-410a has an evaporator at -40 degree C and a high pressure of 1400 kPa. The high temperature cycle uses R-134a with an evaporator at 0 degree C and a high pressure of 1600 kPa. Find the ratio of the two cycles mass flow rates and the overall COP The enthalpy values are …Saturation Pressure-Temperature Data for R410A (psig)*. Temp (°F) Pressure. Temp (°C)Residential 410a system as follows: Liquid line: ~400psi. ~ 30 subcool. Vapor line: 105psi. ~30 superheat. The LLFD does not feel cold. The TXV is backed all the way out.Temperature Calculator. This script determines the gas pressure based on temperature of R410a refrigerant.

You can see that this R410A pressure chart includes high and low side pressures at temperatures ranging from -60 °F to 155 °F. Higher temperature equates to higher pressure. Here are 4 examplesof how you can use this chart: Example 1: What is the pressure of r410a at 72 degrees Fahrenheit? We can see that at … See moreThe operating pressure of 410a on an 85 degree day is 254.6 psig. Example 3: What are 410a pressures on a 70 degree day? The operating pressure of 410a on a 70 degree day is 201.5 psig. Temperature and pressure chart for refrigerants R22, R410A, R12, R134A, R401A, R409A, R502, R404A, R507A, R408A and R402A. Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications! 4 Using Table 2, select the column which is closest to the measured vapor pressure. 5 Scroll down the column to find your calculated superheat. 6 Read the required vapor line temperature at the intersection. (°F) If the measured vapor line temperature does not agree with the required vapor line. 7 temperature, add refrigerant to lower ...The formula used in the R410a Subcooling Calculator is straightforward and is as follows: Subcooling (SC) = Liquid Line Temperature (LLT) – Saturation Temperature (ST) Where: Subcooling (SC) signifies the sought-after subcooling value. Liquid Line Temperature (LLT) pertains to the temperature of the liquid refrigerant in the liquid line ...Good Subcooling Value for R-410A: Similar to superheat, the ideal subcooling value for R-410A can vary depending on factors like system design and operating conditions. However, a common target for R-410A systems is to achieve a subcooling value in the range of 8 to 15 degrees Fahrenheit (°F) or approximately 4.4 to 8.3 degrees Celsius (°C).90 95 100 105 110 115 120 125 130 135 140 145 150 11.6 14.9 18.5 22.5 26.9 31.7 36.8 42.5 48.6 55.2 62.3 70.0 78.3 87.3 96.8 107 118 130 142 155 170 185 201 217 235 254 274 295 317 340 365 391 418 446 476 507 539 573 608 Physical Properties of Refrigerants Environmental Classification Molecular Weight Boiling Point (1 atm, ˚F) Critical ...This screenshot of the Ref Tools app shows the vapor line pressure of R410A at saturation at 39°F. Notice how the slider has been set to DEW point (inside the orange box). Before we even hook up our gauges/probes, we know the system operating pressures should be within +/- 10 PSI of: Liquid Pressure: 356.5 PSIG. Vapor Pressure: 116.1 PSIGIf the condenser saturation pressure for an R-22 system is 226.4 psig and the condenser outlet temperature is 90 degrees, what is the condenser subcooling? a. 110 degrees b. 90 degrees c. 20 degrees d. 10 degrees . Show transcribed …Apr 22, 2020 ... This tends to be around 60 PSI to 85 PSI for R-22 and 105 PSI to 143 PSI for R-410A and is dependent upon operating conditions. On the high- ...psig °f psig °f psig °f psig °f psig °f 12; –37.7. 114

Step 1. A cascade system with one refrigeration cycle operating with R-410a has an evaporator at -40 degree C and a high pressure of 1400 kPa. The high temperature cycle uses R-134a with an evaporator at 0 degree C and a high pressure of 1600 kPa. Find the ratio of the two cycles mass flow rates and the overall COP The enthalpy values are …

At what pressure? [1 Pt] (d) Use interpolation with. Saturated vapor R-410A at 60 oC has its pressure decreased to increase the volume by 10% while keeping the temperature constant. (b) What are the final T-v states? Is it superheated or subcooled? [2 Pts] (c) What is the closest v you can find in the table at 60 oC? At what pressure? [1 Pt]R-410A 5121846-TIM-B-0517 MODELS: NHT25, ... 15 Hole Locations For Reading Coil Pressure Drop . . . . . . 23 16 NHT25 - Pressure Drop Vs. Cfm Across Dry Indoor Coil 24 ... Entering Air Temperature Degrees °F Cooling DB/WB Heating DB1 1. Heating Min/Max temperatures apply to steam and hot water coils. NOTE: Do not apply steam to hot water …The chart displays temperature values (in degrees Fahrenheit or Celsius) against pressure values (in pounds per square inch gauge, or PSIG), allowing for …pressures and refrigeration capacity than R-22. The compositions of Freon™ 407C and Freon™ 410A are as follows: HFC-32 HFC-125 HFC-134a Freon™ 407C (R-407C), wt% 23 25 52 Freon™ 410A (R-410A), wt% 50 50 — Because Freon™ 407C and Freon™ 410A are mixtures of HFCs, they have zero ODP. Table 1 lists the chemical names and formulae …Physical Properties Of R22. In parallel to using the R22 PT chart, professionals will usually need to know some of the following R22 physical properties: R22 liquid density at -69°C: 1.49 g/cm 3. R22 gas density at 15°C: 3.66 kg/m 3. Triple point temperature: -115.76K. Critical pressure: 49.36 bar. Heat capacity ratio at 86°F: 1.178253.just swopped out two 2.5 ton lenox coils and condensers r-22 with two new 410a 2.5 ton coils and condensers easy swop but now the space isn't dropping temp and my dischage air temp is 59 degrees but f … read moreIn this HVAC Training Video, I show the R-22 and R-410A Range of Operating Pressures on Air Conditioning Systems! I show why we Measure Pressures and Tempera...

Roku home screen easter eggs.

Stetler insurance danville pa.

Refrigerant Pressure - Temperature Chart. Pressure values are displayed for R-22, R-410a, R-407c, R-134a and R-404a refrigerants. Items Displayed in Red shows pressure in inches of Mercury. Items Displayed in Black shows pressure in pounds per inch gauge. Data points are reproduced based on available information.At 90 degrees Fahrenheit or less, the low-side should be near 30 PSI. There is a problem if the pressure is too much lower or higher. ... At these operating conditions, the discharge pressure is around 400 Psig. R-410A operates at 50 to 70% higher pressures than the R-22. What is the 134a refrigerant’s suction pressure?Refrigerant Pressure Temperature Chart - PT Chart for R-410A, R-134A, and R-22. These are currently the three most widely used refrigerants on the market today for HVAC applications in residential and commercial use. R-22 refrigerant is the king and used widely in the residential and commercial markets followed by R-134A which is used in ...R-410A Environmental Classification HFC Molecular Weight 72.6 Boiling Point (1atm,°F) -61.0 Critical Pressure (psia) 691.8 Critical Temperature (°F) 158.3 Critical Density (lb./ft^ 3) 34.5 Vapor Density (bp,lb./ft^ 3) 0.261 Heat of Vaporization (bp,BTU/lb.) 116.8 Global Warming Potential (CO2 = 1.0) 2088 ASHRAE Standard 34 Safety Rating A1Oct 31, 2023 · Normal operating temperatures for R-410A systems typically range between 35 to 60 degrees Fahrenheit (1.7 to 15.6°C) for the evaporator coil temperature and 90 to 135 degrees Fahrenheit (32.2 to 57.2°C) for the condenser coil temperature. Sat. R-407C R-407C R-410A Temp R-22 Liquid Vapor Liquid R-11 R-123 (°F) Pressure Pressure Pressure Pressure (PSIG) High Elevation 5,000 feet R-409A R-409A R-401A R-401A R-401B R-401B R-12 R-134a Liquid Vapor Liquid Vapor Liquid Vapor Pressure Pressure Pressure Pressure Pressure Pressure Sat. Temp (°F) Red Numerals - …The R-410A high-pressure manifold gauge and hose set must have a 4000 psig burst pressure and 800 psig working pressure. The high pressure gauge on a service manifold set has a continuous scale, usually calibrated to read from 0 to 500 psig. This does not mean the gauge set is actually rated for use up to 500 psia.If you see a liquid line pressure that is more than 30 degrees saturation above outdoor temperature (like a 440 PSI liquid pressure on an R410a system on a 90-degree day), do not proceed until you have further addressed the possible causes of high head, regardless of what the superheat or subcool might be reading.Refrigerant Type: R-134a, R-410a Maximum Operating Temperature: 250 °F, 121 °C Maximum Operating Pressure: 870 psi, 60 bar Minimum Burst Pressure: 4355 psi, 300 bar Vacuum Pressure Rating: 200 Microns External Leak Rate: 0.1 Ounces of Helium per Year at Operating Pressure Range Vibration Resistance: Conforms to UL10975 80 85 90 95 100 105 110 115 Cooling Pressure (PSI) ... Outdoor Temp (°F) Refrigerant Pressure vs. Temperature Charts for Pioneer Split Systems (R410a) 68 115 119 123 127 131 135 139 143 147 ... common refrigeration expertise in determining the correct operating pressures, based on the actual conditions. Ind. Title: Temperature-Pressure ... ….

(View the Pressure Temperature Chart pictured below for reference) Again, say you have a low side pressure of 76 psi on a HVAC system containing R-22 refrigerant, view the pressure temperature chart and find 76 psi and follow it across to the R-22 column. The evaporator saturation temperature on the chart, reads 45 degrees Fahrenheit.90 terms. maggiehartill. Preview. Basic damage control. 91 terms. fevrierkaylee. ... Saturated R-410A at a pressure of 95 psig will change at a temperature of. ... If the evaporator outlet temperature on an R-410A system is 50 degrees Fahrenheit and the evaporator superheat is 10 degrees Fahrenheit, what is the evaporating pressure of the ...Mar 16, 2024 · The core of the calculator’s functionality is the formula it uses to relate temperature and pressure. Since the relationship for R-410A is specific and non-linear, a general formula might look like this: [P = a + bT + cT^2 + dT^3 + \ldots] where: (P) is the pressure in PSI or bar, (T) is the temperature in degrees Celsius or Fahrenheit, 90 terms. maggiehartill. Preview. Basic damage control. 91 terms. fevrierkaylee. ... Saturated R-410A at a pressure of 95 psig will change at a temperature of. ... If the evaporator outlet temperature on an R-410A system is 50 degrees Fahrenheit and the evaporator superheat is 10 degrees Fahrenheit, what is the evaporating pressure of the ...Online R454B pressure temperature chart spanning from -40°F to 150°F temp. Printable PDF version of R454B PT chart you can take with you on the job. There are several brand names for R454B: Opteon XL41, Solstice 454B, and Puron Advance. This is a blend of R32 (68.9%) and R1234yf (31.1%). It has a very low boiling point of -59.5°F (-50.9°C).Good Subcooling Value for R-410A: Similar to superheat, the ideal subcooling value for R-410A can vary depending on factors like system design and operating conditions. However, a common target for R-410A systems is to achieve a subcooling value in the range of 8 to 15 degrees Fahrenheit (°F) or approximately 4.4 to 8.3 degrees Celsius (°C).Below we list a dozen causes of high head pressure in an air conditioner or heat pump compressor motor. Of these, debris clogging or malfunctioning TXVs seem to be the most common problems. Air contamination in the … system charge chart - refrigerant 410a pressure at suction service port (psig) connect pressure gauges to suction and liquid ports on unit. measure air temperature to outdoor coil. place an "x" on the appropriate chart where the suction and liquid pressures cross. if "x" is below ambient temperature line, add charge and repeat step 3. R410a pressures at 90 degrees, Testing 410A pressures on LG mini split. Couple of questions on pressures. Sticker on outdoor unit says low side pressure design pressure of 240 PSIG pressure (high side pressure 450 PSIG). Manual says pressure range of 120-135 PSIG at outside ambient temperature of 95 degrees F. I’m assuming I can check for pressure at 240 when NOT …, Digital Fieldpiece Gauges: https://amzn.to/2LFjNnKR410A Equipment: https://amzn.to/2xv6AG5My Favorite Tool: https://amzn.to/3NIFJuOTools We Recommend: https:..., About Ferguson HVAC. Ferguson HVAC is a national distributor of residential and commercial heating and cooling equipment, parts and supplies. HVAC contractors across the country rely on us for the best unitary and ductless equipment brands and for a wide-range of HVAC products including accessories, controls, air distribution supplies, and …, Becoming bilingual opens up a whole new world of different people, different cultures, and different emotions. It also takes a huge time commitment—one that many of us can't dedica..., The automotive HVAC gauge readings should be between 35-40 PSI on the low side and 145-160 on the high side, assuming an ambient temperature of 70 degrees Fahrenheit. ACLAB Note: The respective gauges should have a pressure temperature chart to align the ambient temperature with the proper pressure., The automotive HVAC gauge readings should be between 35-40 PSI on the low side and 145-160 on the high side, assuming an ambient temperature of 70 degrees Fahrenheit. ACLAB Note: The respective gauges should have a pressure temperature chart to align the ambient temperature with the proper pressure., Table of Contents. Refrigerant R-410A Pressure Temperature Chart - This R410A PT Chart will help you when charging a system that utilizes R-410A. Furthermore, …, Pressure (psig) Temp (°C) Liquid Vapor Liquid Vapor Liquid Vapor Liquid Vapor ... -10 36,5 36,3 -23,3 40 118,8 118,4 4,4 90 275,4 274,5 32,2 140 542,5 541,4 60 ..., It can be used for recharging refrigerant, or to diagnose an a/c system based on pressure readings from your gauges. Ambient Temperature (°F) Low Side. High Side. 110°. 50-55 psi. 335-345 psi. 105°. 50-55 psi. , Low-pressure switches on Carrier equipment using R-410A are usually set to open at about 50 psi and close at about 100 psi. Note: Heat pumps operating in the..., Things can get overwhelming fast when you have too many things to do. Author Greg McKeown, author of Essentialism: The Disciplined Pursuit of Less suggests a system of ranking and ..., The normal working R410A system with similar condensing temperature is 120 degrees and 45 degrees evaporator saturation temperatures come with a high …, -40-39-38-37-36-34-33-32-31-30-29-28-27-26-24-23-22-21-20-19-18-17-16-14-13-12-11-10-9-8-7-6-4-3-2-1: 0: 1: 2: 3: 4: 6: 7: 8: 9: 10: 11: 12: 13: 14: 16: 17: 18: 19 ..., Refrigerant Pressure Temperature Chart - PT Chart for R-410A, R-134A, and R-22. These are currently the three most widely used refrigerants on the market today for HVAC applications in residential and commercial use. R-22 refrigerant is the king and used widely in the residential and commercial markets followed by R-134A which is used in ..., Physical Properties Of R22. In parallel to using the R22 PT chart, professionals will usually need to know some of the following R22 physical properties: R22 liquid density at -69°C: 1.49 g/cm 3. R22 gas density at 15°C: 3.66 kg/m 3. Triple point temperature: -115.76K. Critical pressure: 49.36 bar. Heat capacity ratio at 86°F: 1.178253., pressure of about 250 psi at an outdoor temperature of 95°F. With R-410A, the same unit will operate under the same conditions with a suction pressure of 118 psi and a discharge pressure of 400 psi, as shown in Figure 1 on the next page. (Note that in most cases, equipment designed for R-22 cannot use R-410A because of this difference in operating, Refrigerant Pressure - Temperature Chart. Pressure values are displayed for R-22, R-410a, R-407c, R-134a and R-404a refrigerants. Items Displayed in Red shows pressure in inches of Mercury. Items Displayed in Black shows pressure in pounds per inch gauge. Data points are reproduced based on available information., 90 95 100 105 110 115 120 125 130 135 140 145 150 11.6 14.9 18.5 22.5 26.9 31.7 36.8 42.5 48.6 55.2 62.3 70.0 78.3 87.3 96.8 107 118 130 142 155 170 185 201 217 235 254 274 295 317 340 365 391 418 446 476 507 539 573 608 Physical Properties of Refrigerants Environmental Classification Molecular Weight Boiling Point (1 atm, ˚F) Critical ..., R22 changes from a liquid to a gas in the evaporator coils of the air handler. Normal temperatures: With compressor running and as reference, on a 90 degree F. day: - Goodman runs 45degrees F on low pressure side and 115degrees F on high pressure side. - 2 ton York runs 40degrees F on low pressure side and 110degrees F on high pressure …, I'm old enough to remember when inline skating was cool. And I've lived long enough to see it become (sorta) cool again. Has anything once cool ever so quickly become less cool tha..., The low side pressure of a typical R410A mini split is between 110-140 psi depending on the operating conditions. Though it can vary, the low side pressure of a mini split should not fall below 100 psi or raise beyond 160 psi. The working pressure of mini splits is depending on factors such as the weather and cooling load., Mar 1, 2020 ... refrigerator? R22 R410a ... SUBCOOLING= Liquid line temp(90 Degrees F.) ... R-22 and R-410A Refrigerant Operating Pressures on Air Conditioning ..., Building a plywood box? Use these wooden blocks to help two pieces meet at 90 degrees. Watch Joe Truini's Simple Solution on Today's Homeowner! Expert Advice On Improving Your Home..., Which statement about R-410A is true. Mixtures of R-410A with air can become combustible, never mix R-410A with air or oxygen for either leak testing or pressurizing a system. A recovery cylinder which is half full of recovered R-410A at 80 degrees F, in the absence of non-condensables, will be pressurized to: 237 psig., The latitude of the North Pole corresponds to 90 degrees north latitude. Latitude lines around a globe are the horizontal lines, where 0 degrees latitude corresponds to the equator..., Feb 14, 2024 · The operating pressure of 410a on an 85 degree day is 254.6 psig. Example 3: What are 410a pressures on a 70 degree day? The operating pressure of 410a on a 70 degree day is 201.5 psig. , BP. BP. BP. -114.6°F. -115.6°F. -126.1°F. Before adding refrigerant charge, evacuate to proper vacuum level to remove non-condensable gases and to evaporate and remove moisture in the system. This chart shows the vacuum level and the temperature at which water will vaporize., Pressure-Temp Chart-40-35-30-25-20-15-10-5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 11.6 14.9 18.5 22.5 26.9 31.7 36.8 42.5 48.6 55.2 62.3 70.0 78.3 87.3 96.8 107 118 130 142 155 170 185 201 217 235 254 274 295 317 340 365 391 418 446 476 507 539 573 608 Physical Properties of ..., This guide evaluates 25 of the best online degrees for accounting students. Updated April 14, 2023 thebestschools.org is an advertising-supported site. Featured or trusted partner ..., The temperature glide for R-410A is less than ____ degrees Fahrenheit over air conditioning and refrigerating operating ranges. ... A. 50 psig B. 30 psig C. 70 psig D. 90 psig. A. 50 psig. When a blend is ... R-410A systems use a high pressure switch that will open at approximately: A. 500 psig plus or minus 10 psig B. 610 psig plus or minus 10 ..., Pressure Controls & Thermostats. Go back; Pressure Controls & Thermostats; Pressure Controls; Fan Speed Controls; Oil Failure Controls; ... Copper Elbow - 90 degree - 3/4" - F/M (R410A) LR - 3 Pack - CE1290FML4103PK. Home. Products & Resources. Product Range. COPPER TUBE, FITTINGS & INSULATION. Copper Fittings., Let’s use the target superheat formula and calculate this manually: Target Superheat (R-410A) = (3 × 69°F – 80°F – 105°F) / 2 = 11.0°F. We see that the target superheat for R-410A refrigerant in this system is 11°F. You can use the target superheat calculator above to get to this result much quicker., Jul 4, 2015 · Head on 410 at 100° will be in the 375 - 400 range depending on surrounding conditions, sun, heat load inside, dirt on the coil. high suction pressure could be from a high load, bad compressor, bad-wrong-nonexistant metering device. There are a multitude of things that can cause pressures to be high or low depending on the situation.