Low suction/High head. I have a carrier 38QRF024300 with a 40QNQ024 unit I be been having issues with. Originally my readings were 157# suction (410A) and 275# head reading 7,5.2, and 4.1 amps when RLA is 12.8; with 5 degrees of subcooling. Ambient is 80 in parking garage.

Low suction pressure high head pressure. Number 2 is incorrect, metering device part depends on system to system. High load is correct. Look at your liquid line temps, subcooling and approach temps. They will help diagnose high head issues. There is another cause of high head pressure, mismatched (higher btu) compressor. Different refrigerant in the system.

ABOUT THE AUTHOR: Jim Frankland is a mechanical engineer who has been involved in all types of extrusion processing for more than 40 years. He is now president of Frankland Plastics Consulting, LLC. Contact [email protected] or (724)651-9196. Use drag- and pressure-flow equations to analyze fluctuating output.

Suction Head. Based on the Energy Equation - the suction head in the fluid close to the impeller *) can be expressed as the sum of the static and velocity head: h s = p s / γ liquid + v s 2 / 2 g (1) where. h s = suction head close to the impeller (m, in) p s = static pressure in the fluid close to the impeller (Pa (N/m 2), psi (lb/in 2))Low blood pressure, or hypotension, is generally not a concern and requires no treatment in healthy people, according to WebMD. Treatment of hypotension may require treatment of an...Mar 24, 2023 · In addition to a malfunctioning TXV, other factors that can cause high subcooling include a dirty condenser coil or restricted airflow over the condenser. Low Suction pressure/ low head pressure. A bad TXV can also cause low suction pressure and low head pressure in an HVAC system by restricting the flow of refrigerant into the evaporator coil. lower suction pressure and high discharge pressure. Study with Quizlet and memorize flashcards containing terms like which of the following is NOT a symptom of a hermetic system that is low on refrigerant?, frost on the suction line indicates;, an increase in head pressure causes _____ refrigerant to flow through a capillary tube. and more.Shortage of refrigerant. A leaking compressor head gasket. A leaking compressor suction valve. Debris in expansion valve or screen. How to Fix Low Suction Pressure Issues. If …High discharge temperatures can indicate minimal movement of refrigerant. Because the refrigerant isn't being pumped at design rates it stays in the condenser for a longer period of time and is cooled more, hence lower head pressures, and in turn, if the compressor is not pumping well, you will see elevated suction pressures. Reply.Low capacity, a starved evaporator, high superheat, and low suction pressure are all symptoms of a (n) _____ A. inefficient condenser B. inefficient compressor C. refrigerant overcharge D. low refrigerant charge. C. High discharge pressure, high suction pressure, high subcooling, and high compression ratios are all symptoms of a (n) _____. ...Jan 9, 2017 · This will cause the following symptoms: Low evaporator (suction) pressure; High evaporator and compressor superheats; Low compressor amp draw; Short-cycling on the low-pressure control; Somewhat high discharge temperature; Low condensing (head) pressure; Low condenser split; and.

180 suction line pressure 320 discharge 10 degree temp split. No temp difference across the filter drier. I cleaned coils and checked airflow just to eliminate the variables. I recovered the refrigerant, changed the filter drier, charged about 2lbs before starting the compressor and the low side shot right up to 170. System holds about 8 lbs total.91. If the head pressure is too high: A. the relief valve should open and let excess refrigerant pass to receiver. B. close in on the suction valve. C. the relief should open before the high-pressure cutout. D. the high-pressure cutout switch should operate before the relief value opensHigh head suction pressure. High suction pressure is a common problem in the cooling systems. It can cause due to improper functioning of the compressor. If the compressor is not delivering sufficient refrigerant to the system, the suction pressure will increase accordingly. One can understand the high head suction pressure with a better study ...Suction Head. Based on the Energy Equation - the suction head in the fluid close to the impeller *) can be expressed as the sum of the static and velocity head: h s = p s / γ liquid + v s 2 / 2 g (1) where. h s = suction head close to the impeller (m, in) p s = static pressure in the fluid close to the impeller (Pa (N/m 2), psi (lb/in 2))Low suction/low head pressures. Bevearage air Prep table not cooling-. R134a, AEA4440YXA hermetic. pressures were about what they should be for a cap tube system (roughly 150/25 psi) but just blowing around warm air. Plate said 7 oz of R134A but I pull out 2 lbs so I evacuate and recharge with 7oz and now the pressures are way down.Scroll Troubleshooting Solution Chart - Copeland A/C Specific. Deep Vacuum Conditions. Deep vacuum can cause arcing damage to the Fusite pins. Models built after September 1991 have an internal vacuum protection and stop pumping when the pressure exceeds approximate. 10:1. Scroll compressors should never be used to evacuate a system, allowed to ... Heat pressure is low and suction pressure is high. What is the problem?, In a 2-ton capillary tube system, the unit does not develop full capacity. Head pressure is high, suction pressure is high, and there is no superheat. Jan 9, 2017 · This will cause the following symptoms: Low evaporator (suction) pressure; High evaporator and compressor superheats; Low compressor amp draw; Short-cycling on the low-pressure control; Somewhat high discharge temperature; Low condensing (head) pressure; Low condenser split; and.

Head pressure, or high-side pressure, is crucial in HVAC units, particularly for the efficient function of the air conditioner’s condenser. Maintaining proper refrigerant …If a high head pressure is detected, you will need to call your local professionally licensed air conditioning service team. What Determines High Head Pressure. A 410A system who have 400-418 PSIG on the high side, while the lower side is 120-130 PSI. If it is more than this, it is considered high.404a pressures in low. I have a r-404a roof-top condensing serving a walk in freezer. pressures are 235 psi head pressure and a 28psi suction pressure. Outdoor ambient is 30degress and indoor box temperature is about 20degrees. System has a head pressure control on roof for hot gas. Wondering if pressures sound right.higher head pressure and higher subcooling. When any refrigeration system is low on refrigerant it will usually have: low suction and low head pressure. What can cause high superheat in a TEV metered evaporator? ... What combination of symptoms only occurs on a unit with an inefficient compressor? Low head pressure and high suction pressure ...Jul 19, 2005 · In the cooling mode this will result in low suction pressure and low discharge pressure. Sub cooling would be extra high. However, heatpumps can't always be charged accurately using sub cooling alone. Usually "a stuck check valve" can be freed-up by using a strong magnet.

Thinkscript aggregation period 9 minutes.

The compressor is still cooling, but not to its rated capacity, which can cause refrigerated products to spoil faster and frozen products to begin to thaw. There are three main reasons why a compressor will simultaneously have a low head pressure and a high suction pressure: 1. Bad (leaky) compressor valves; 2. Worn compressor rings; and.After the system runs for a while, raise the RPMs up to about 1,500. The system should be about 25 to 30 psi on the low side and 200 to 250 psi on the high side. If the ambient temperature is higher or lower than normal (70 to 80°F) the pressures will go up or down accordingly.However, systems that pump low-pressure, high-temperature liquids are most likely to experience problems. Some examples include: ... This is the minimum acceptable pressure head at the pump suction.Terms in this set (54) In order for a system to operate correctly, the high side of the system must have enough _____. Vapor pumped, heat removed from condenser, vapor space. If there is a lack of refrigerant in a system, each pounds of refrigerant will not completely __________. Condense on the high side. When a system is undercharged, the ...What is the result of raising the temperature of the room in which a low-pressure chiller is located? Leak test and repair the chiller. What should be done to reduce refrigerant loss from a purge unit on a R-123 chiller? 15 psig. A rupture disc on a recovery vessel for low-pressure refrigerants relieves at; Industrial process refrigeration. A ...

410A System with high head. I went to do a maintenance on a 410A Trane system today, when I came up on the trane I noticed it was running like a 450 pound head pressure, the first thing i thought was why in the world would it be so high, so I cleaned the cool, checked filters, checked txv bulb position, everything checked out although there ...System Information R22 2.5 ton: Low Side: 115. High Side: 240. Return Air: 83. Suction Line Temp: 75. Measured Super heat: 5. Super heat should be around 15. Low superheat is an indication that liquid refrigerant not changing state in the evaporator and is possibly flooding back to the compressor.We would like to show you a description here but the site won’t allow us.Study with Quizlet and memorize flashcards containing terms like In a 2-ton capillary tube system, the unit does not develop full capacity. Heat pressure is low and suction pressure is high. What is the problem?, In a 2-ton capillary tube system, the unit does not develop full capacity. Head pressure is high, suction pressure is high, and there is no …Our diagnostic sheet shows that liquid line restrictions cause low suction pressure and normal to low head pressure, not high head pressure.The high head pressure may be due to ____. high ambient temperatures or reduced airflow through the condenser an overcharge of refrigerant, especially if it is a critically charged system Correct! All of the above. a thick coating of dirt and grime on the condenserLow suction pressure and high head pressure occur when there’s a drop in refrigerant pressure in the AC system, coupled with elevated output pressure in the …Low head pressure. Decreased capacity. Increased head pressure. Low compression capacity. 1 of 100. Term. High pressure gauge reads 146 psig and the liquid line temperature at the condensing unit is 95°F. What is the operating systems sub-cooling? ... Low suction pressure, High discharge pressure.Thread: Low suction - High Head. Thread Tools. Show Printable Version; 02-09-2005, 12:35 AM #1. saillar. View Profile View Forum Posts View Forum Threads ... If you attempt to bring up the suction pressure by adding more refrigerant, you'll be stymied by high head pressure and a suction pressure that does not come up much (with a …If the suction pressure is low, check the user manual. High Suction Pressure. A high suction pressure can be caused by an excessive load or overfeeding of the expansion valve. Another reason for this could be an open overloader of the compressor. ... The high head pressure is pretty common in water source heat pumps, …💐👌🤝Air conditioner head Pressure low, & Head pressure High & Suction pressure Low what’s Problem How many types problem creating learn very useful informa...How to Fix Low Suction Pressure Issues. If there is excessive moisture in system: replace the drier. If you find a flattened or kinked hose: replace the hose. If the compressor pistons have worn out: replace the compressor. If there is a shortage of refrigerant: add refrigerant. If there is a leaking compressor head gasket: replace the head gasket.

If a high head pressure is detected, you will need to call your local professionally licensed air conditioning service team. What Determines High Head Pressure. A 410A system who have 400-418 PSIG on the high side, while the lower side is 120-130 PSI. If it is more than this, it is considered high.

High discharge temperatures: High head pressures or high superheat causes this problem. The compressor discharge line can be measured quickly using an infrared thermometer on a dull section of pipe. ... Low suction pressure: Extremely low suction pressures can be checked using the pressure module and your DMM. Install it …Low suction pressure and high head pressure occur when there’s a drop in refrigerant pressure in the AC system, coupled with elevated output pressure in the compressor. The primary culprit behind this condition is a faulty or malfunctioning TXV valve .💐👌🤝Air conditioner head Pressure low, & Head pressure High & Suction pressure Low what’s Problem How many types problem creating learn very useful informa...At room temperature, it will boil if the absolute pressure is less than about 0.4-psia. Water has low vapor pressure; other substances may have high values and, while numerically different, work similarly. Consider three examples of a tank providing different suction heads as a function of the tank pressure: Figure 3a. Tank open to …OPERATING PRESSURE POINTS “Systems using R-410A operate at higher pressures [than R-22],” points out the Field Diagnostics team. “For example, to produce an evaporating temperature of 40 degrees F and a condensing temperature of 115 degrees, the suction and head pressures would be 83 psia and 257 psia in an R-22 system, while they would be 133 and 406 psia, respectively, in an R-410A ...Peal. 3 posts · Joined 2009. #46 · Jul 12, 2009 (Edited) I think bwalley is correct. 3 things will cause high head pressure; poor air flow across condenser, overcharge, or non condensable in system. Recover charge, check system for leaks, pull vacuum, and weigh in new charge.Low suction pressure high head pressure is a common issue that can occur in an air conditioning (AC) system. This condition is characterized by a decreased …Jan 1, 2013 · The outdoor TXV is stuck open, you can try putting the bulb in ice water to see if TXV closes and also putting the bulb in hot water to see if it opens. Watch your suction pressure. You need to check airflow, you should be moving 1400 cfm. Put unit in emergency heat mode and check temp rise. Sometimes, however, problems will occur and this will include anything from low suction pressure to low compressor discharge pressure. High compressor discharge pressure will also be a problem that needs to be attended to right away. Basically, a discharge pressure is the pressure that is being generated on a gas compressor’s output side ...Definition. of NPSH —The margin of pressure over vapor pressure, at the pump suction nozzle, is Net Positive Suction Head (NPSH). NPSH is the diference between suction …

Indian spice shop springfield.

San bernardino usps.

When measuring evaporator superheat on a commercial system that has a long suction line, the pressure reading should be taken at the A. Compressor inlet B. Evaporator outlet C. Condenser ... A TXV with an external equalizer is used on A. Evaporators with a high pressure drop B. Evaporators with a low pressure drop C. High temperature ...Head pressure 190 Suction Pressure 90 Suction line temp 54 inside temp 75 wetbulb 69 So ive been thru this problem b4 with the low head high suction so i assume piston or a-coil . I open up the duct and the other hvac guy has put in a 3ton acoil . I told the neighbor that he should replace the acoil with a 2 1/2 ton .High head pressure AND low suction pressure both contribute to high compression ratios. Lately, air conditioning manufacturers have attempted to drop …High head pressure. Which of the following indicates air in a low-pressure system? To prevent freezing of water in the appliance. ... Charging liquid R245fa into a low-pressure refrigeration system under a vacuum greater than 18 inches Hg vacuum can cause the; 25 mm Hg absolute.If the suction pressure is low, check the user manual. High Suction Pressure. A high suction pressure can be caused by an excessive load or overfeeding of the expansion valve. Another reason for this could be an open overloader of the compressor. ... The high head pressure is pretty common in water source heat pumps, …Technician saw pressure fluctuations of 450-580 or so high side and a 10 psi range on low side centered around 132 or so. Oddly, they shot to their highs together, bled down to the lows over about 40 seconds, shot back up, ad infinitum.I have a suction pressure of 70, converted temp of 41, suction line temp of 51, head pressure of 250, converted temp of 117, head line temp of 96. Air entering condenser is 82 and exit is 100. Air entering evaporator is 76 and exiting is 52.180 suction line pressure 320 discharge 10 degree temp split. No temp difference across the filter drier. I cleaned coils and checked airflow just to eliminate the variables. I recovered the refrigerant, changed the filter drier, charged about 2lbs before starting the compressor and the low side shot right up to 170. System holds about 8 lbs total. ….

R22 boiling point: -40.8 degree Celsius at atmospheric pressure (sea level or 1 ATM) R22 density: 3.66 g/cm 3, in gas form - this is a colorless gas. R22 molar mass: 86.47 g/mol. R22 gas cylinder identification: light green. R2 status: no longer in active use, replaced with R458A.Subaru engines have a radiator and water channel design that uses pumped and pressurized coolant to stabilize its internal temperature. Unlike most internal combustion engines, ins...we note (and you probably know better than I) that making sense of any refrigerant pressure reading requires also a note of the ambient temperature. If we take 75°F as an example point, R410 low side typical pressure would be about 120 psi and the high side between 410-420 psi. Your high side is a little low.lower suction pressure and high discharge pressure. Study with Quizlet and memorize flashcards containing terms like which of the following is NOT a symptom of a hermetic system that is low on refrigerant?, frost on the suction line indicates;, an increase in head pressure causes _____ refrigerant to flow through a capillary tube. and more.410A System with high head. I went to do a maintenance on a 410A Trane system today, when I came up on the trane I noticed it was running like a 450 pound head pressure, the first thing i thought was why in the world would it be so high, so I cleaned the cool, checked filters, checked txv bulb position, everything checked out although there ...In addition to a malfunctioning TXV, other factors that can cause high subcooling include a dirty condenser coil or restricted airflow over the condenser. Low Suction pressure/ low head pressure. A bad TXV can also cause low suction pressure and low head pressure in an HVAC system by restricting the flow of refrigerant into the …1. Check Refrigerant Pressures. Hook-up refrigerant gauges to the pressure ports on the unit. Blue --> "True Suction" Low Pressure. Red --> High Pressure (Small liquid line) Allow the unit to run for 5-10 minutes. Monitor pressures as the system operates. Normal R-22 Suction Pressure = 60 - 80psig. 2.The users should set high and low alarms on the EdP output to keep the DP tightly controlled while increasing the flow rate. If the pump doesn’t generate 120 feet total head at the 55 gpm flow rate, this could be your first indication of an operational or mechanical issue. Check the suction pressure and ensure it is greater than NPSHr.Low amp draw. Short cycle on low-pressure control (LPC). High Discharge Temperature Somewhat high discharge temperatures are caused from the higher superheats from the evaporator being starved of refrigerant. The compressor is now seeing a lot of sensible heat coming from the evaporator and suction line, along with its heat of …Low suction/low head pressures. Bevearage air Prep table not cooling-. R134a, AEA4440YXA hermetic. pressures were about what they should be for a cap tube system (roughly 150/25 psi) but just blowing around warm air. Plate said 7 oz of R134A but I pull out 2 lbs so I evacuate and recharge with 7oz and now the pressures are way down. Low suction pressure high head pressure, Low suction pressure and high head pressure occur when there’s a drop in refrigerant pressure in the AC system, coupled with elevated output pressure in the …, What is High Head Pressure for 410A . High head pressure for 410A is an indication of a system that has lost its ability to evaporate refrigerant correctly. This can be caused by many things including low charge, clogged air filters, restricted airflow, or dirty coils. High head pressure creates higher discharge temperatures and forces the ..., To troubleshoot non-condensable issues, it is important to observe key performance indicators. If the system exhibits high head pressure, low suction pressure, poor cooling, increased sub-cooling, and high compression ratios, it may indicate the presence of non-condensables. Shutting off the system and equalizing pressures can provide valuable ..., Terms in this set (24) When a redfrigeration systems's suction line is noticeably cold instead of just being cool, it probably contains___refrigerent. low-pressure liquid. When a refrigeration systems's liquid linw is noticably hot instead of just being warm. probably contains ____ refrigerant. high-pressure vapor. , Comparing head pressure with suction pressure reveals much about an HVAC unit. High or low readings indicate potential issues. Regular checks help catch problems early. For example, if head pressure is too high but suction remains normal, there might be a blockage. Conversely, low head pressure could suggest a leak somewhere in the system., 410a low suction pressure. I injected super seal in a 410a system that had a tiny leak that I could not find. 2 years later I come across the problem of low suction pressure normal head pressure. Replaced txv and had same problem. Replaced compressor and had the same problem. Could the super seal be clogging the txv or …, Jan 1, 2013 · The outdoor TXV is stuck open, you can try putting the bulb in ice water to see if TXV closes and also putting the bulb in hot water to see if it opens. Watch your suction pressure. You need to check airflow, you should be moving 1400 cfm. Put unit in emergency heat mode and check temp rise. , Jun 24, 2011 · High Suction Pressure! I have a 3Ton Carrier Heat Pump unit using 410A that has extremely high suction pressure around 250PSI. I also have a low liquid line pressure around 300PSI and my sub-cooling is around 40-50 Degrees. I have checked for a stuck liquid line solenoid but this system does not have one, and I checked the reversing valve and ... , The outdoor TXV is stuck open, you can try putting the bulb in ice water to see if TXV closes and also putting the bulb in hot water to see if it opens. Watch your suction pressure. You need to check airflow, you should be moving 1400 cfm. Put unit in emergency heat mode and check temp rise., Mar 9, 2020 · This small amount of heat to reject will cause a low condensing pressure and temperature. Most of the refrigerant will then be stored in the condenser and receiver, simulating a pumped-down refrigeration system. Symptoms of a liquid line restriction include: Low evaporator (suction) pressure; High superheats; , Upon examination, we found the system low on charge, cycling on the low pressure control. Repaired the leak, recovered refrigerant (because we didn't know what was in there). Evacuated to 500 microns and charged with HP62. Low side pressure is around 18psi and high side pressure is 375psi and tripping the high pressure cut out., Suction pressure: 110ish. head pressure: 400 reached 550 when I put my wind breaker over the top - Condenser coil was clean. Subcooling: 50. Superheat: 35. Liquid line temp: 68. Suction line temp: 63. Even temps at both sides of the filter drier. Reply. 06-11-2020, 04:58 PM #2., Low suction pressure and high head pressure occur when there’s a drop in refrigerant pressure in the AC system, coupled with elevated output pressure in the compressor. The primary culprit behind this condition is a faulty or malfunctioning TXV valve ., The yen weakened past 150 to the dollar Thursday, adding pressure on officials to intervene in the markets to shore up the currency. Jump to The Japanese yen weakened to above 150 ..., Study with Quizlet and memorize flashcards containing terms like The technician finds a high split across an evaporator coil this is an indicator of what?, The technician observes low gauge pressures on an AC unit this is an indicator of?, You find superheat by subtracting suction temperature from suction pressure T/F? and more., 410a low suction pressure. I injected super seal in a 410a system that had a tiny leak that I could not find. 2 years later I come across the problem of low suction pressure normal head pressure. Replaced txv and had same problem. Replaced compressor and had the same problem. Could the super seal be clogging the txv or …, Mar 13, 2017 · NPSH Required (NPSHR): The minimum pressure required at the suction port of the pump to keep the pump from cavitating. NPSH or Net Positive Suction Head is a very important part of a pumping system. The systems NPSH A must be higher than the pump’s NPSH R in order for proper pump performance and to eliminate the risk of cavitation, which can ... , Technician saw pressure fluctuations of 450-580 or so high side and a 10 psi range on low side centered around 132 or so. Oddly, they shot to their highs together, bled down to the lows over about 40 seconds, shot back up, ad infinitum., Understanding the relationship between head and suction pressure can help diagnose problems early and avoid costly repairs or replacements. If you’re experiencing high …, R22 boiling point: -40.8 degree Celsius at atmospheric pressure (sea level or 1 ATM) R22 density: 3.66 g/cm 3, in gas form - this is a colorless gas. R22 molar mass: 86.47 g/mol. R22 gas cylinder identification: light green. R2 status: no longer in active use, replaced with R458A. , If you don't mind getting your hands a little dirty, some petroleum jelly can increase the suction power of your plunger to help with particularly stubborn clogs. If you don't mind..., Upon examination, we found the system low on charge, cycling on the low pressure control. Repaired the leak, recovered refrigerant (because we didn't know what was in there). Evacuated to 500 microns and charged with HP62. Low side pressure is around 18psi and high side pressure is 375psi and tripping the high pressure cut out., Low suction pressure causes. low suction pressure is developed in the refrigeration system. Some of the most probable causes are as below, The coil is covered with dust or frost. Restriction in the refrigerant line. Filters and strainers are dirty. Faulty fan motor. Low room temperature. Faulty compressor., We would like to show you a description here but the site won’t allow us. , Number 2 is incorrect, metering device part depends on system to system. High load is correct. Look at your liquid line temps, subcooling and approach temps. They will help diagnose high head issues. There is another cause of high head pressure, mismatched (higher btu) compressor. Different refrigerant in the system., Low suction/low head pressures. Bevearage air Prep table not cooling-. R134a, AEA4440YXA hermetic. pressures were about what they should be for a cap tube system (roughly 150/25 psi) but just blowing around warm air. Plate said 7 oz of R134A but I pull out 2 lbs so I evacuate and recharge with 7oz and now the pressures are way down., In the cooling mode this will result in low suction pressure and low discharge pressure. Sub cooling would be extra high. However, heatpumps can't always be charged accurately using sub cooling alone. Usually "a stuck check valve" can be freed-up by using a strong magnet., Yeah I'm pretty sure it's an cfm flow because the furnace is a 90,000 btu furnace but I did put it on low speed still wondering if maybe it's still too much flow considering how big it is for only 1,000 sqft house.., A bad check valve on an air conditioner, heat pump or similar HVACR equipment can show up as abnormally low or abnormally high suction line pressures, or as abnormally low or high superheat. Experts suggest using an IR heat gun or similar tempeature measuring tool to check the tempeature of the refrigerant line on each side of the valve., Came across another Rheem recently with a high head pressure in heat mode. Its a RPPL. Head pressure slowly climbs to above 600, suction pressure is normal not low at all. Airflow inside is okay... static pressure is .7inWc. Coils are clean. In cooling mode the charge looks damn near perfect... 11 degrees subcooling and 9-11 degrees superheat., Fig. 3.55 illustrates this by plotting the pump discharge head vs. flow for high- and low-suction tank conditions. The control valve, however, tries to maintain a steady pressure. As a result, the flow rate varies as the suction pressure varies. In some cases, the flow rate may drop to below the recommended minimum at very low head conditions., 💐👌🤝Air conditioner head Pressure low, & Head pressure High & Suction pressure Low what’s Problem How many types problem creating learn very useful informa..., To troubleshoot non-condensable issues, it is important to observe key performance indicators. If the system exhibits high head pressure, low suction pressure, poor cooling, increased sub-cooling, and high compression ratios, it may indicate the presence of non-condensables. Shutting off the system and equalizing pressures can provide valuable ...