Install Oracle's Sun Storage Common Array Manager 6.9.x software and perform initial configuration for RAID and JBOD open systems storage arrays. This document describes how to configure and monitor Oracle's Sun Storage, StorageTek, and FlexLine arrays using the Sun Storage Common Array Manager software, version 6.9.0.

Common array manager software. Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options …

Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not.

The Sun StorageTek Common Array Manager software provides you with an easy-to-use interface to configure, manage, and monitor Sun StorageTek storage arrays. New features in Release 6.0.0: Enhancements to Auto Service Request (ASR) functionality. Support for Sun StorageTek FLX240, FLX280, and FLX380 Arrays. Software; User manual. Sun Storage Common Array Manager Array Administration Guide C H A P T E R. 1. ... “Logging Out of the Management Software” on page 10. About the Browser Interface. The browser interface provides …Goal. This article documents Sun Storage 6140 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of …About Array Registration. When you install the management software on a new host, the Storage System Summary page displays as blank with no arrays listed. On all subsequent logins to the Common Array Manager, the Storage System Summary page is displayed with the arrays you registered with the software.K-FRAMEWORK 3. The ALL-IN-ONE K-array software will assist you in every step of your project. From the ACOUSTICAL SIMULATION to the system TUNING. -available for Windows and Mac-. 1. Network Management: Discover all amps connected to the network and decide which ones to add to your workspace. The network section also provides …快速入门指南. 本指南可帮助您了解 Oracle Sun Storage Common Array Manager 软件的基本安装步骤。. 如果要从先前版本升级或者需要其他信息,请参见《Sun Storage Common Array Manager 安装和设置指南》。. 相关文档链接请参见文档、支持和培训。.

Sun Storage 2540 Array - Version Not Applicable and later Sun Storage Flexline 380 Array - Version Not Applicable and later All Platforms Goal. Automatic Service Request (ASR) is a feature of the array management software that monitors the array system health and automatically notifies Oracle when critical events occur. Download popular programs, drivers and latest updates easily No specific info about version 6.9. Please visit the main page of Sun Storage Common Array Manager CLI on Software Informer. Sun StorageTek Common Array Manager Software Release Notes, Release 6.1: PDF: Sun StorageTek Common Array Manager Software Installation Guide, v6.1: HTML: PDF: Sun StorageTek Common Array Manager CLI Quick Reference, v6.1: PDF: Sun StorageTek Common Array Manager User Guide for the J4000 Array Family, Version 6.1.2: HTML: PDF Sun Storage Common Array Manager Software Release Notes. Use this document for instructions about how to download the latest Oracle’s Sun Storage Common Array Manager software and learn about new features, related documentation, system requirements, notable bug fixes, and known issues for the CAM 6.9.0_20 product release.From Preferences > Advanced > Proxies (or a similar path, depending on your browser), add the Sun Storage Common Array Manager management host name to the “No Proxy for” section. Recent Firefox versions might require you to accept and add a security certificate prior to bringing up the authentication page.Sun StorageTek Common Array Manager Software Release Notes, Release 6.1: PDF: Sun StorageTek Common Array Manager Software Installation Guide, v6.1: HTML: PDF: Sun StorageTek Common Array Manager CLI Quick Reference, v6.1: PDF: Sun StorageTek Common Array Manager User Guide for the J4000 Array Family, Version … Instructions to download Common Array Manager (CAM). Log in to My Oracle Support. Click on the "Patches & Updates" tab on the top bar. In the "Patch Name or Number" field, enter the patch number (ie: 10272123 or 141474-01) corresponding to the CAM software or patch you want to download. Click on "Search".

Download popular programs, drivers and latest updates easily Sun Storage Common Array Manager JBOD Service Advisor is developed by Oracle Corporation and is used by 1 user of Software Informer. The most popular versions of this product among our users are: 6.7, 6.8 and 6.9.Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not.Uninstall all versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.1.0.10 release. Later versions do not have to be removed. 2. Decide on the installation type you want to perform, and go to one of these sections: Installing the Full Management Software; Custom Installation Options The SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring. E-mail alert notification Goal. This article documents Sun Storage 6140 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of …

Flights from paris to barcelona.

How to Download Common Array Manager (CAM) Software and Patches [Doc ID 1296274.1] Note - Each array should be managed by one CAM management host only. Installing the management software on more than one host to manage the same array can cause discrepancies in the information reported by CAM.The Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays. The software includes a distributed architecture which enables you to manage Sun/StorageTek Storage platforms throughout your company, regardless of location.Sun StorageTek Common Array Manager Software Installation Guide. This chapter describes how to install the management software using a graphical interface or the …The Common Array Manager software can manage arrays with either in-band and out-of-band connections at the same time. Copying Configuration Files and In-Band Management. If you are going to copy a configuration file to a management host that will have in-band communication with the array, ...The Sun StorageTek Common Array Manager Installation Software provides three installation-related wizards: GUI software installer - Enables you to use a graphical user interface wizard to install a selection of applications to support a local or remote …

About Array Registration. When you install the management software on a new host, the Storage System Summary page displays as blank with no arrays listed. On all subsequent logins to the Common Array Manager, the Storage System Summary page is displayed with the arrays you registered with the software.The Sun StorageTek Common Array Manager software provides you with an easy-to-use interface to configure, manage, and monitor Sun StorageTek storage arrays. New features in Release 5.1.3: Sun Connection (Auto Service Request): registration, telemetry, and automated case generation. Support for 2500 Series Arrays.Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not.This article documents Sun StorageTek 2540 (FC) Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose …The SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring. E-mail alert notificationVersion. 4.21.7.0 Latest. Release Date. Oct 5, 2020. Type. Software - System Management. Download Software. The HPE Smart Storage Administrator (HPE SSA) is a web-based application that helps you configure, manage, diagnose, and monitor HPE ProLiant Smart Array Controllers and now other storage devices as well, such as … 1. Use the IP address of the management host to access the management software: https://cam-management-host:6789 2. Log in as root (Solaris OS) or Administrator (Windows). The Oracle Java Web Console page is displayed. Next Steps Go to the Sun Storage Common Array Manager Software Installation and Setup Guideor Online Help for information The Sun StorageTek Common Array Manager software is a web-based management software that provides both a browser interface and a command-line interface (CLI) for configuring and managing arrays on an external management host. Management host platforms can be: Note - Windows XP Home Edition is not supported. 5. From the Oracle Java Web Console page, select Sun Storage Common Array Manager from the Storage section of the Oracle Java Web Console page. Providing Site Information. When you open the Common Array Manager after a first-time installation, the General Configuration page displays. 1. Enter the required site and contact information for your site. Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web-based browser interface is the primary interface for configuring, managing, and monitoring the system. Command-line interfaces options are also ... The Sun StorageTek Common Array Manager (CAM) software suite is your main tool for Sun Storage array enclosure management, monitoring, and service capabilities. The software has both a secure browser interface and a command-line interface (CLI). CAM is supported for use with Solaris, Linux and Windows platforms. Viewing Sun Storage …

The SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring.

Software: Common Array Manager, version 6.8.1. License Term: Perpetual (subject to termination under the SLA) Licensed Unit: Software Copy. Licensed unit Count: Unlimited. Permitted Uses: You may reproduce and use the Software for Your own Individual, Commercial, or Research and Instructional Use, subject to and conditioned on. Sun StorageTek 2500 Series Array Regulatory & Safety Manual. HTML. PDF. Sun Storage Common Array Manager Software 6.10 Documentation. LIBRARY. Sun Storage Common Array Manager Software 6.9 Documentation. LIBRARY. Sun Storage Common Array Manager Software 6.8 Documentation. LIBRARY. Predict Your Design. Line Array Calculator (LAC) is a software tool providing two-dimensional acoustic simulation and mechanical validation of flown and ground-deployed VTX Series and SRX900 sound systems. Line Array Calculator’s enhanced acoustical modeling includes color SPL mapping, 0dB Isobar, and SPL attenuation modes with …Sun StorageTek 2500 Series Array Regulatory & Safety Manual. HTML. PDF. Sun Storage Common Array Manager Software 6.10 Documentation. LIBRARY. Sun Storage Common Array Manager Software 6.9 Documentation. LIBRARY. Sun Storage Common Array Manager Software 6.8 Documentation. LIBRARY. 快速入门指南. 本指南可帮助您了解 Oracle Sun Storage Common Array Manager 软件的基本安装步骤。. 如果要从先前版本升级或者需要其他信息,请参见《Sun Storage Common Array Manager 安装和设置指南》。. 相关文档链接请参见文档、支持和培训。. Feb 9, 2016 · yannickhaas (Yannick432) February 9, 2016, 1:13pm 6. On Oracle Support I can not download the software without support for the Unit. They also don’t want to sell support / the software for the Unit. So I hope someone here has a copy of the Manager…. DoctorDNS (DoctorDNS) February 9, 2016, 2:11pm 7. If that is the case, then asking for ... See the Sun Storage Common Array Manager Software Release Notes for a list of supported operating system platforms. For more information about CLI commands, see the sscs man page and the Sun Storage Common Array Manager CLI Guide. Installing the Administrator Host CLI Software . 1. Start the installation using the steps for your OS. To Assign an IP Address to Each Ethernet Port. . Access the Sun StorageTek Common Array Manager software: Open a web browser and enter the IP address of the management host: https://management-host:6789. management-host is the IP address of the machine where you installed the management software. https://cam-management-host:6789. cam-management-host is the IP address or host name of the host where you installed the Common Array Manager software. 3. Log in as root (Solaris) or administrator (Windows). For Solaris OS and Linux, root already exists for the machine on which you installed the software.

Boston to iceland.

Farm and fllet.

Sun StorageTek Common Array Manager Software Release Notes. This document contains important information about Release 6.0.0 of the Sun StorageTek Common Array Manager software or information that was not available at the time the product documentation was published. Read this document so that you are aware of issues or …Sun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed.Start a DHCP server on the same subnet, then reboot the 2500 Series Array. Using the serial port interface (see Using the Serial Port Interface to Assign IP Addresses). Using the Sun StorageTek Common Array Manager (see the Sun StorageTek Common Array Manager Software Installation Guide). Configuring Static IP AddressingCommon Array Manager Software Features. The Sun StorageTek Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek storage arrays. New features in Release 6.0.1. iSCSI support for Sun StorageTek 2510 Array Minimal (CLI-only) installationDownload popular programs, drivers and latest updates easily Sun Storage Common Array Manager Online Help is a software that provides a simple, unified interface for managing Sun Storage arrays. It simplifies deployment, simplifies the storage environment, and increases utilization. Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not. 2 Sun StorageTek Common Array Manager Software 6.4 Release Notes • April 2009 About Sun StorageTek Common Array Manager Software The Sun StorageTek Common Array Manager (CAM) software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays. CAM …The Sun StorageTek Common Array Manager Installation Software CD provides three installation-related wizards: GUI software installer - Enables you to use a graphical user … ….

K-FRAMEWORK 3. The ALL-IN-ONE K-array software will assist you in every step of your project. From the ACOUSTICAL SIMULATION to the system TUNING. -available for Windows and Mac-. 1. Network Management: Discover all amps connected to the network and decide which ones to add to your workspace. The network section also provides … 快速入门指南. 本指南可帮助您了解 Oracle Sun Storage Common Array Manager 软件的基本安装步骤。. 如果要从先前版本升级或者需要其他信息,请参见《Sun Storage Common Array Manager 安装和设置指南》。. 相关文档链接请参见文档、支持和培训。. In the Common Array Manager software, go to the Port Summary page and verify that the target ports (one for each controller) are in an up status and note there IP addresses and ports. If you need to change the port IP addresses, use the Port Details page. You can enter a new IP address or set DHCP.Array Manager software provides a comprehensive storage management solution in an integrated, graphical view. From a single location, Array Manager enables you to configure and manage local and remote storage attached to a server, while the server is online and continuing to process requests.Sun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed. 1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su - 5. If needed, change the array management default IP addresses using the serial port interface. Configuring IP Addressing. 6. Install the Sun StorageTek Common Array Manager software. 7. In the software, register the storage array and perform the basic administration setup. Note: for storage array configuration, use the iSCSi steps that follow. Common array manager software, Start a DHCP server on the same subnet, then reboot the 2500 Series Array. Using the serial port interface (see Using the Serial Port Interface to Assign IP Addresses). Using the Sun StorageTek Common Array Manager (see the Sun StorageTek Common Array Manager Software Installation Guide). Configuring Static IP Addressing, Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web-based browser interface is the primary interface for configuring, managing, and monitoring the system. Command-line interfaces options are also ... , From Preferences > Advanced > Proxies (or a similar path, depending on your browser), add the Sun Storage Common Array Manager management host name to the “No Proxy for” section. Recent Firefox versions might require you to accept and add a security certificate prior to bringing up the authentication page., About Array Registration. When you install the management software on a new host, the Storage System Summary page displays as blank with no arrays listed. On all subsequent logins to the Common Array Manager, the Storage System Summary page is displayed with the arrays you registered with the software., In the Common Array Manager software, go to the Port Summary page and verify that the target ports (one for each controller) are in an up status and note there IP addresses and ports. If you need to change the port IP addresses, use the Port Details page. You can enter a new IP address or set DHCP., About Array Registration. When you install the management software on a new host, the Storage System Summary page displays as blank with no arrays listed. On all subsequent logins to the Common Array Manager, the Storage System Summary page is displayed with the arrays you registered with the software., Sun StorageTek Common Array Manager Software Release Notes, Release 6.1.2 ..., https://cam-management-host:6789. cam-management-host is the IP address or host name of the host where you installed the Common Array Manager software. 3. Log in as root (Solaris) or administrator (Windows). For Solaris OS and Linux, root already exists for the machine on which you installed the software., 快速入门指南. 本指南可帮助您了解 Oracle Sun Storage Common Array Manager 软件的基本安装步骤。. 如果要从先前版本升级或者需要其他信息,请参见《Sun Storage Common Array Manager 安装和设置指南》。. 相关文档链接请参见文档、支持和培训。. , Oracle’s Sun Storage Common Array Manager includes the following documentation integrated within the software: Sun Storage Common Array Manager online help Available via the “Help” button within the Sun Storage Common Array Manager browser interface. Service Advisor Provides guided, FRU-replacement procedures with system feedback for all, Sun StorageTek Common Array Manager The Sun StorageTek Common Array Manager software is a key component for the initial configuration and operation of the Sun StorageTek 2500 Series Array hardware. It is installed on a management host cabled to the array via out-of-band Ethernet (cables for this connection are provided). To obtain a general ... , Sun Storage 2540 Array - Version Not Applicable and later Sun Storage Flexline 380 Array - Version Not Applicable and later All Platforms Goal. Automatic Service Request (ASR) is a feature of the array management software that monitors the array system health and automatically notifies Oracle when critical events occur. , Windows: Uninstall all versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.1.0.10 release. Later versions do not have to be removed. Check that previously installed services, such as the Storage Automated Diagnostic Environment, are not performing a function on the array over the Ethernet …, How to Download Common Array Manager (CAM) Software and Patches [Doc ID 1296274.1] Note - Each array should be managed by one CAM management host only. Installing the management software on more than one host to manage the same array can cause discrepancies in the information reported by CAM., What You Get with Common Array Manager Software. Licensing Optional Premium Features 4. 4. Documentation. 5. System Requirements 6. Supported Arrays. 6. …, 3. Install the desired version of the Common Array Manager software as described in the Installation Guide in the doc directory of the software installation CD or download. Note –The procedure will be similar to “Installing the Common Array Manager Software” on page 7, but the prior release may have differences. 4. , Sun StorageTek Common Array Manager Software Release Notes. This document contains important information about Release 6.0.0 of the Sun StorageTek Common Array Manager software or information that was not available at the time the product documentation was published. Read this document so that you are aware of issues or …, Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options …, Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web-based browser interface is the primary interface for configuring, managing, and monitoring the system. Command-line interfaces options are also ... , The intent of this document is to explain how to download Common Array Manager (CAM) and its patches from My Oracle Support (MOS) - Patches & Updates. The 3 steps are: …, Sun Storage Common Array Manager (CAM) has the ability to collect support-based configuration and logs for Sun Storage 2500, 2500-M2, J4000, F5100, 6000 and Flexline Arrays. ... Instead, you use the management software provided with the Unified Storage System. Please refer to J4200/J4400 Array System Overview. Solution. …, Software: Common Array Manager, version 6.8.1. License Term: Perpetual (subject to termination under the SLA) Licensed Unit: Software Copy. Licensed unit Count: Unlimited. Permitted Uses: You may reproduce and use the Software for Your own Individual, Commercial, or Research and Instructional Use, subject to and conditioned on., With new arrays, the mapping of the access LUN to the default domain is installed at the factory. If you lose this mapping, before installing in-band, use out-of-band management and the Common Array Manager …, OUTPUT. Sun Storage Common Array Manager Software Release Notes Release 6.10 for Solaris OS Host l. Review important late-breaking information about Sun Storage Common Array Manager 6.10. Download. Sun Storage Common Array Manager Version: 6.10.0 Third Party License README l. This Third Party License README …, This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see theSun Storage Common Array Manager Software Installation and Setup Guide. See Documentation, Support, and Training for documentation links. , Included with the Sun Storage Common Array Manager installation package and DVD is Microsoft Operations Manager 2005 (MOM), an IT services management tool. MOM is a separate application that integrates with Sun Storage Common Array Manager, and is delivered as a zip file with the other Sun Storage Common Array Manager installation files., Sun StorageTek Common Array Manager contains two user interfaces, a full command line and a web UI. The web UI has not been evaluated for accessibility and is not included in this VPAT. ... Software shall not use flashing or blinking text, objects, or other elements having a flash or blink frequency greater than 2 Hz and lower than 55 Hz. …, With new arrays, the mapping of the access LUN to the default domain is installed at the factory. If you lose this mapping, before installing in-band, use out-of-band management and the Common Array Manager software to re-map the access LUN to the default domain. See the Online Help in the software for more information about mapping., Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not., Note - For other arrays managed by the Sun StorageTek Common Array Manager, firmware, this release may require special firmware instructions. Refer to the Sun StorageTek Common Array Manager Software Release Notes, Release 6.1.2 (or later) for the latest firmware information and a list of firmware files for your array., Sun StorageTek Common Array Manager contains two user interfaces, a full command line and a web UI. The web UI has not been evaluated for accessibility and is not included in this VPAT. ... Software shall not use flashing or blinking text, objects, or other elements having a flash or blink frequency greater than 2 Hz and lower than 55 Hz. …, 快速入门指南. 本指南可帮助您了解 Oracle Sun Storage Common Array Manager 软件的基本安装步骤。. 如果要从先前版本升级或者需要其他信息,请参见《Sun Storage Common Array Manager 安装和设置指南》。. 相关文档链接请参见文档、支持和培训。. , Sun StorageTek Common Array Manager Software Release Notes. This document contains important information about Release 6.0.0 of the Sun StorageTek Common Array Manager software or information that was not available at the time the product documentation was published. Read this document so that you are aware of issues or …