When adjusting the valve, make no more than one turn of the stem at a time and pay close attention to the change in superheat to avoid overshooting the desired setting. Furthermore, how does one go about adjusting a thermostatic expansion valve? Find the adjustment needle on the thermostatic expansion valve and turn it to the desired setting.

Adjusting a sporlan txv. Sporlan Division Products can and do fail without warning for many rea-sons. Design all systems and equipment in a fail­safe mode, so that fail­ ure of these products and related accessories will not endanger persons or property. Pressure Rating: The maximum internal pressure of the Y1037, Y1210 and Y1244 valves is 500 psig (34 bar).

Sporlan 108628 - SBFSE-C-C 3/8" x 1/2" ODF Thermal Expansion Valve w/ 30" Capillary (2-1/4 to 3 Ton)- Specifications: REFRIGERANT TYPE: R-404A APPLICATION: Commercial Refrigeration THERMOSTATIC CHARGE: C NOMINAL CAPACITY (TON): C INLET CONNECTION: 3/8" ODF OUTLET CONNECTION: 1/2" ODF EQUALIZER METHOD: Externally Equalized CAPILLARY LENGTH (INCH ...

thermostatic expansion valve replacement parts item number part number and description drawings on pages 3 thru 10 valve type and quantity of part required per valve er rc f ef bf ebf sbf g eg c s ebs p small o large o 183019 772-000 inlet strainer 1/4" sae 1 183015 3008-000 1 1 183017 1538-000 3/8" sae 1 1 1 183023 588-000 1 183025 589-000 ...This Parker Sporlan webinar training module will discuss Thermostatic Expansion Valves (TEVs) as part of our HVAC Excellence presentation. Learn everything y...To reduce the superheat, turn the adjusting stem COUNTER-CLOCKWISE.Toincreasethesuperheat,turntheadjustingstem Should a Sporlan thermostatic expansion valve (TEV) be adjusted after installation? 52° F C O N V E R T E D T O T E M P . OBTAIN SUCTION PRESSURE . . . 69 PSIG (at bulb) 52 ° 40° 12 ° …This Parker Sporlan webinar training module will discuss how to properly select solenoid valves to ensure dependable operation in refrigerant flow system. F...Watch this video to find out about the Pass-Thru Adjustable Wrench Set from Crescent, which can be used as an adjustable wrench, a pipe wrench, and a socket wrench. Expert Advice O...

• The intended design life of the Electric Expansion Valve is 15 years, providing that the valve is installed and operated within the design intent, and the system is free from contaminants. ... • Sporlan is not responsible for any damage which may be caused by misuse or by installation of parts, accessories or controls which are not on the ...Sporlan Division 206 Lange Drive Washington, MO 63090 phone 636 239 1111 fax 636 239 9130 [email protected] www.sporlanonline.com Product Features: • Can reduce system energy consumption by lowering head pressure • For harsh refrigeration environ-ments; cold rooms, supermarket cases and transport applications • Provides smooth system …Expansion Valve (Orifice Tube) Replacement Cost. Service Location. SELECT YOUR VEHICLE. $420.66 - $1,770.96. Price range for all vehicles. ( 47) Most cars nowadays have air conditioner. We love to have the feel of the cool air on those hot summer days, and we don't often think about what's involved in making sure the air conditioning runs ...On an adjustable valve, increasing the spring tension/force results in lower flow and higher superheat, and decreasing the spring …equalized expansion valve is specifi ed, that particular evaporator used a refrigerant distributor and the net P across the distributor assumed was 25 psi for R-134a and 35 psi for R-22, R-404A and 507. If conditions differ from above, valve selections should be made from Sporlan Bulletins 10-9, 10-10 and 20-10.

This diagram shows the forces of the TXV’s flexible diaphragm. Courtesy, Sporlan Division, Parker Hannifin Corp. January 26, 2021. The thermostatic expansion valve (TXV or TEV) is a metering device located between the refrigeration system’s liquid line and the evaporator. It is a rather complex valve with a remote bulb feedback …There are several metering devices in a typical system, including the thermostatic expansion valve (TEV or TXV), automatic expansion valves, electronically-governed expansion valves, balanced port TEVs, superheat and multi-circuited TEVs, and evaporators. The two basic functions of a metering device include: Feeding refrigerant to the evaporator.These features of the TXV valve are explained below. Another name for the TXV valve is the thermal expansion valve. By controlling the flow of the liquid refrigerant with the TXV valve, the evaporator on your air conditioning unit or heat pump will run more efficiently. The TXV valve also serves to protect the mechanical reliability of the unit.As a world leader in refrigerant flow controls, Sporlan Division of Parker Hannifin continues to meet the challenges of the future. Our growing line of products for R-290 (Propane) sets new standards for robust design and advanced technology. This condensed catalog contains product information specifically for R-290 (Propane) applications.

Tobias truvillion net worth.

Bryan does an in-depth review of how to adjust a thermostatic expansion valve, also known as a TXV, TEV, or TX Valve. He explains why one would adjust a TXV ...For more information about our products visit us at www .sporlan .com . Bulletin 30-21- Page 3 3-Way Heat Reclaim Valves B5D, 8D, 12D, 16D, 8D-HP, 12D-HP, SB5D, S8D, S12D, S16D, S8D-HP, S12D-HP ... liquid pressure at the expansion valve inlet, but also to assure the availability of quality hot gas at the reclaim heat exchanger. See Sporlan ...This Parker Sporlan webinar training module will discuss Thermostatic Expansion Valves (TEVs) - Supermarket Metering Devices. This is part of our former Supe...SD-289 - Sporlan TEV Installation and Instructions SD-414 - Sporlan FX TEV Installation and Instructions Sporlan Replacement Parts - Bulletin 122 Product Demos & Tutorials; HVACR Tech Tip: Introduction to Thermostatic Expansion Valves (TEVs) How to Adjust Thermostatic Expansion Valve Superheat for HVACR Applications Adjust and optimize superheat in less than 15 minutes. TXV Superheat Tuner is now part of Ref Tools, the essential, all-in-one mobile app for air conditioning and refrigeration technicians. Ref Tools gives you access to the tools, guidance, support, and information you need—on the job and in the field.

Connect any Sporlan step motor valve to the SMA-12 by matching wire color to terminal color. Any 12 VDC bipo-lar step motor may be tested with the SMA-12. Phase one leads should be connected to the black and white terminals, Phase two leads should be connected to the red and green terminals. 2. Select a step rate with the selector knob. 3.Precaution: Don't fix the adjustable screw very far since a little bit of force is required to set the fixing. Learn in this guide for technicians covers how to adjust a thermostatic expansion valve (TXV), how these parts works and when they need to be adjusted.6. Select the Sporlan Selective Thermostatic Charge. Select the charge according to the design evaporating temperature from the Table on page 3. Refer to Bulletin 10-9 for a complete discussion of the available Sporlan Selective Thermostatic Charges. Selection Example – Refrigerant 22 Application: medium temperature refrigerationThe Sporlan OVE-20CP100 Thermostatic Expansion Valve is ideal for light commercial and all residential HVACR applications. It is designed to regulate the flow of refrigerant, providing steady compressor performance while maintaining uniform ability and pressures. This model has a nominal capacity of 20 tons and features 7/8 ODF inlet x 1-3/8 ...The Sporlan Type ER balanced port thermostatic expansion valve has a brass bar stock body. The ER valve has ODF connections in a variety of commons sizes, and has an optional inlet strainer available. There is also an option for a 15% bleed port, if required.They are adjusted manually; the Sporlan ADRSE-2, from the video below, is adjusted using an Allen key. Adjusting the valve inwards will allow more hot gas to flow through the valve, and backing out the adjustment will allow less hot gas to flow through the valve. When setting up the valve, you may need to simulate a low-load condition. Sporlan Division Products can and do fail without warning for many rea-sons. Design all systems and equipment in a fail­safe mode, so that fail­ ure of these products and related accessories will not endanger persons or property. Pressure Rating: The maximum internal pressure of the Y1037, Y1210 and Y1244 valves is 500 psig (34 bar). TXV Installation Instructions. DO NOT oil threads. Before installing the TXV, install one. O-ring on the Liquid Line Fitting. Install the other O-ring on the Inlet Tube Assembly. See Figure 3. Connect the TXV by hand to ensure proper mating of threads. Tighten until bodies "bottom" or a definite resistance is felt.WARNING: This product can expose you to chemicals including Lead, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov. Description Substitutes Documents. KT43VC - Charge element, R22 family, C charge (high temp), 5' capillary.Parker Hannifin Corporation, Sporlan Division 206 Lange Drive • Washington, MO 63090 USA www.sporlan.com PED NAMEPLATE DATA TYPE DESCRIPTION MAX. RATED PRESSURE (BAR) TS (ºC) FLUID CAPACITY (L) DN CATEGORY FOR GROUP 1 FLUIDS SERI-G(S) SERI-G 5X5 ODF 48.0-45°C to 60°C 0.06 10 SEP SERI-G 5ODFX5ODM 0.06 10 SEP SERI-G 5X7 ODF 0.07 20 SEP SERI ...

Parker Expansion Valve Quick Reference. Parker Expansion Valve - Quick Reference. Parker Hannifin orporation, roadview, IL USA 800-742-2681 P-109-0712. Orifice R-12 / R-134A R-404A / R-507 R-22 / R-407 R-410A AAA* N/A 1/8 to 1/6 1/6 to 1/3 N/A AA 1/6 to 1/4 1/6 to 1/4 1/3 to 1/2 1/3 to 1/2 A 1/2 to 1 1/2 to 1 3/4 to 1½ 3/4 to 1½ 1 to 2 1 to 2 ...

FSE2C. Expansion valve, standard port, R404A family, external equalizer, 2 tons, 3/8" MFL inlet x 1/2" MFL outlet, C charge (medium temp) Connection Size Inlet (In.): Connection Size Outlet (In.): Overall Height (In.): WARNING: This product can expose you to chemicals including Lead, which are known to the State of California to cause cancer ...7__GJE-1-1/2-C 3X4 SAE 5' __7. Sporlan Type G thermostatic expansion valves are designed for use on Air Conditioning and Refrigeration units. They regulate refrigerant flow by maintaining a nearly constant superheat at the evaporator outlet.<br/><br/>.2 / BULLETIN 500-10-HC-CR. The selections are based on load and operating conditions provided by Heatcraft Inc. All selections are based on condensing pressures of 175 psig (R-22), 200 psig (R-404A and R-507), and 10 degree liquid subcooling. Externally equalized valves are used with coils having refrigerant distributors.Quick Reference Guide. SD-324/72016. Controller v. The Sporlan Superheat Control should be installed only by a qualified professional. All other system components (valves and sensors) should be supplied by Sporlan to ensure compatibility and proper operation. There are no user-serviceable components inside the con-troller. Welcome to Parker Sporlan's Virtual Engineer Sizing and Selection Tool Parker Sporlan's Virtual Engineer is an innovative design tool for climate control and refrigeration applications. Save engineering time with three simple steps: Sporlan has a new and improved website! The new Sporlan.com website provides easy access to literature and products as well as our HVACR online learning and training. Find everything from product information to webinars and everything in between. We provide the HVACR information you need to be successful. See the website!With the expansion valve at the Sporlan factory setting, or at a manufacturer's predetermined setpoint, and under the actual minimum load condition, the evaporator pressure regulating valve should be adjusted to the desired setting. Finally, if necessary, the thermostatic expansion valve or valves can be adjusted to the desired superheat settingWhen adjusting both evaporator pressure regulating valves and thermostatic expansion valves, the follow-ing procedure is recommended. With the thermostatic expansion valve at the Sporlan factory setting or at a manufacturer’s predetermined set point, and under the actual minimum load condi-tion, the evaporator pressure regulating valve shouldSo... you’re six weeks into your new life in a new city. So... you’re six weeks into your new life in a new city. Or six months. Or a year. No matter how long it takes, at some poi...A thermal expansion valve is a key element to a heat pump; this is the cycle that makes air conditioning, or air cooling, possible. A basic refrigeration cycle consists of four major elements: a compressor, a condenser, a metering device and an evaporator. As a refrigerant passes through a circuit containing these four elements, air ...

Fuji restaurant spartanburg menu.

Tractor supply near me walmart.

INLET CONNECTION: 3/8" SAE. OUTLET CONNECTION: 1/2" SAE. EQUALIZER METHOD: Externally Equalized. CAPILLARY LENGTH (INCH): 30". STRAINER TYPE: 100 Mesh Removeable. The Sporlan Type BF-EBF-SBF balance ported thermostatic expansion valves have a brass bar stock body with flare or sweat connections, adjustable superheat, long lasting replaceable ...This Parker Sporlan webinar will discuss Thermostatic Expansion Valves as part of the RSES training presentation. Learn everything you need to know about the...Expansion Valve (TXV) - R-410A, 3-Ton, 3/8 in. Inlet, 3/8 in. Outlet. IMPORTANT: Heating, ventilation, air conditioning or refrigeration parts and accessories should only be installed by qualified technicians. Failure to understand and follow the manufacturer's installation and use instructions may result in fire or explosion, electric shock ... One thing to notice is that Hillphoenix has added a note to their NRG case cut sheets saying that the evaporator temperature cannot be more than 4* lower than the recommended value. This is a fairly new CYA note. Setting the higher 58# pressure may help with icing and get more accurate superheat values. Re: Adjusting Sporlan TXV for SH. Adjusting the superheat setting may only serve to mask your problem and should not be undertaken lightly. You should really be sure of your the air volume across the evap and the load its generating. Does the unit have a sight glass, whats the liquid temp, is the TXV bulb secure and placed properly. select a Sporlan Thermostatic Expansion Valve (TEV) with correct capacity, selective charge, external or internal equalizer, etc. See Bulletins 10-9 and 10-10 for complete application information. Equally important is the proper installation, which can determine the success or failure of the entire system. n Valve LocationQ: What is the correct way to diagnose a TXV? A: First, take all of your refrigerant readings and your liquid line and suction temperature at both ends (on a split system). This means superheat, subcooling, suction saturation (evaporator coil temp), and liquid saturation (condensing temp). For a TXV to do what it is supposed to, you need a full ...For example, the same size orifice that feeds 0.96 tons of capacity for R-22 will only feed 0.63 tons for HFC-404A, or 0.56 tons for HFC-422D on a 20° evaporator. As you can see, the capacity of the nozzle’s orifice is greatly affected when switching to or from R-22. Be very careful when working with those so-called drop-in refrigerants for ...TXV FUNCTIONALITY: 1+2: The thermostatic expansion valve (TXV) sensing bulb senses the temperature at the evaporator outlet. Based on that temperature, pressure in the sensing bulb increases or decreases. 3: The increased or decreased pressure is transmitted through the capillary tube to the top half of the power element. 4: …Bryan explains why and how to adjust a TXV and what to consider before doing it. A TXV maintains a constant superheat value at the evaporator outlet, and it … ….

This Parker Sporlan webinar training module will discuss Thermostatic Expansion Valves (TEVs) as part of our HVAC Excellence presentation. Learn everything y... Page 2 / BULLETIN 90-21. When adjusting both evaporator pressure regulators and ther-mostatic expansion valves, the following procedure is recom-mended: With the expansion valve at the Sporlan factory setting or at a manufacturer’s predetermined set point, and under the actual minimum load condition, the evaporator pressure regulator should ...Válvula de expansión termostática - Sporlan - Tipo O. Las válvulas de expansión termostática O de Parker Sporlan están diseñadas para unidades de aire acondicionado y refrigeración. Regulan el flujo de refrigerante al mantener un recalentamiento casi constante en la salida del evaporador.In this video we will cover Balanced Port TXV Download the Airefco App: http://bit.ly/airefco-app And make sure to follow us on socials: https://smarturl.i... One thing to notice is that Hillphoenix has added a note to their NRG case cut sheets saying that the evaporator temperature cannot be more than 4* lower than the recommended value. This is a fairly new CYA note. Setting the higher 58# pressure may help with icing and get more accurate superheat values. Sporlan Division Products can and do fail without warning for many rea-sons. Design all systems and equipment in a fail­safe mode, so that fail­ ure of these products and related accessories will not endanger persons or property. Pressure Rating: The maximum internal pressure of the Y1037, Y1210 and Y1244 valves is 500 psig (34 bar).In the automatic expansion valve, the spring pressure along with the atmospheric pressure acts on the diaphragm and pushes it down. As a result, the needle also tends to move down away from the seat leading to the opening of the valve. The evaporator pressure pushes the diaphragm in an upward direction. Due to this, the needle tends to move in ...If you’re in the market for a new bed, you might want to consider investing in a twin adjustable bed base. These innovative beds have been gaining popularity in recent years and fo...Welcome to Parker Sporlan Chillskills Online Training & Learning. For over 85 years Sporlan has remained committed to strengthening the HVACR industry through education. We are excited to continue our tradition of providing educational HVACR information and training to the industry. Learn from our Parker Sporlan Specialist Training, Wholesaler ...If you’re in the market for a new bed, you might want to consider investing in a twin adjustable bed base. These innovative beds have been gaining popularity in recent years and fo... Adjusting a sporlan txv, The Sporlan FJE-1/2-C valve. I want to set this to the 10F factory setting by the number of turns, without having to run the unit. In my case I have a dual evaporator, and dual TXV's. One is new, The other someone installed without connecting the equalizer, and the adjuster cap is missing, no biggy as it doesn't leak (fortunately) this is a ..., While Sporlan always suggests installing ARI approved matched systems, studies(1) have shown that replacing a fixed restrictor with a TEV on mismatched systems can improve efficiency and increase efficiency ratings from 8.46 SEER to 11.85 SEER. This could equate to an average annual savings of $160. Sporlan provides an energy saving solution, Sporlan's OVE-40CP100 Thermostatic Expansion Valve is ideal for both residential and commercial HVACR applications. With a nominal capacity of 40 tons, it is designed with a 1-1/8 ODF inlet, a 1-3/8 ODF outlet, and is rated for use with R22 or R407C refrigerants. This expansion valve is built for durability, with an equalization type of ..., Standard bleed port sizes are: 5%, 10%, 15%, 20%, 30%, and 40%. Bleed ports are designated by the percentage they increase nominal valve capacity at 40°F evaporator temper-ature. For example, a 2 ton TEV with a 30% bleed will have the capacity of: 2 x 1.3 = 2.6 tons. Refer to Page 17 for Ordering instructions., Thermostatic Expansion Valve - Sporlan - Type BQ. SBQE BODY 3X4X2 ODF. SBQE BODY 3X4X2 ODF. Thermostatic Expansion Valve - Sporlan - Type BQ. SBQE BODY 3X4X2 ODF. SBQE BODY 3X4X2 ODF ... Sporlan Division 206 Lange Drive Washington, MO 63090 USA. Phone:+1 (636) 239-1111. Technical Specifications. Maximum Pressure (psi):, Bulletin 210-60 - Sporlan Thermostatic Expansion Valves Identification SD-14 - Sporlan Thermostatic Expansion Valves Installation, Field Service, and Assembly SD-289 - Sporlan TEV Installation and Instructions SD-414 - Sporlan FX TEV Installation and Instructions Sporlan Replacement Parts - Bulletin 122 Product Demos & Tutorials, Step 4: Measure Initial Superheat. Before making any adjustments to the TXV, you'll need to establish a baseline by measuring the existing superheat. Attach a temperature probe to the suction line near the evaporator coil. Note down the temperature reading. See also Compressor Short Cycling: 6 Proven Solutions., People with adjustment disorder experience a severe response to a stressful event or big change, but the condition is highly treatable. Divorce, illness, or a new job can spark an ..., By Victor Ene. Undertaking a Sporlan TXV superheat adjustment doesn’t have to be a daunting task. In this comprehensive guide, we delve into every aspect you need to know …, An internal equalizer expansion valve, also known as an internal equalizer TXV, doesn't have an electronic part to adjust. It uses fully mechanical-based adjustment by three pressure types from the feeler bulb, internal equalizer port, and spring rod pressure to balance various forces for precise control. It is designed with internal ..., Thermostatic Expansion Valve - Sporlan - Type BQ. SBQE BODY 3X4X2 ODF. SBQE BODY 3X4X2 ODF. Thermostatic Expansion Valve - Sporlan - Type BQ. SBQE BODY 3X4X2 ODF. SBQE BODY 3X4X2 ODF ... Sporlan Division 206 Lange Drive Washington, MO 63090 USA. Phone:+1 (636) 239-1111. Technical Specifications. Maximum Pressure (psi):, 1.TYPE VALVE -Sporlan thermostatic expansion valves are available in three body styles — SAE flare, ODF sol-der, or flange. The first letter or letters stamped on the valve body and shown on the label designates the valve type. Valve types are listed below. 2.REFRIGERANT -Sporlanvalves are available for use with most popular refrigerants., Temperature-Pressure card), and adjust the valve if necessary. Install and tighten seal cap, this cap is the primary seal. Thermostatic Expansion Valve for Converting Non-Adjustable BI and I, or for Replacement of Adjustable Bottom Cap Assemblies on RI Valves Installation Instructions ® For KA-I/BI Bottom Cap Kits ⚠ WARNING – USER ..., First, measure the superheat right at the evaporator outlet in the same general location as the TXV bulb and equalizer. In most cases, the superheat at that point should be 5-10 degrees, but refer to the manufacturer's specs when in doubt. In some cases, you will not have a pressure port at the evaporator, so you must rely on a pressure reading ..., The TXV cannot be adjusted open or closed, it is a modulating valve. Turning the adjustment stem clockwise will only increase spring pressure causing a higher superheat. Turning the adjustment stem counterclockwise will decrease spring pressure reducing superheat. When an operating refrigeration system stops working, the TXV may have lost its ... , This is a Brand New OEM Upgraded 1.5-3 Ton Aspen/Sporlan A-coil TXV Valve. It is designed for R-22 refrigerant. Thanks for looking and good luck! The thermostatic expansion valve controls one thing only: the rate of flow of liquid refrigerant into the evaporator. This is achieved by monitoring temperature and pressure in the refrigerant system., Page 2 / BULLETIN 90-21. When adjusting both evaporator pressure regulators and ther-mostatic expansion valves, the following procedure is recom-mended: With the expansion valve at the Sporlan factory setting or at a manufacturer’s predetermined set point, and under the actual minimum load condition, the evaporator pressure regulator should ..., For more tips, visit our website, http://www.edgetekhvac.com., This Parker Sporlan webinar will discuss Thermostatic Expansion Valves as part of the RSES training presentation. Learn everything you need to know about the..., The ONLY way to verify operation of a TEV is to check the superheat and adjust it to your need. 10 degrees might be fine for AC purposes, but I need things quite a bit cooler than that for refrigeration sometimes. Reply. 10-21-2013, 06:42 AM #11., • The intended design life of the Electric Expansion Valve is 15 years, providing that the valve is installed and operated within the design intent, and the system is free from contaminants. ... • Sporlan is not responsible for any damage which may be caused by misuse or by installation of parts, accessories or controls which are not on the ..., Adjust the valve in a clockwise direction to the desired setting. Step 6. Repeat Steps 1 and 2 and readjust if required. The CRO-4 has a 3/8" adjustment screw on top of the adjustment housing. The CRO(T)-6 and CRO(T)-10 have a valve cap and a hex adjustment in the adjustment hous-ing. Remove the cap and use a 1/4" hex wrench for the, Watch this video to find out about the Pass-Thru Adjustable Wrench Set from Crescent, which can be used as an adjustable wrench, a pipe wrench, and a socket wrench. Expert Advice O..., 6. Select the Sporlan Selective Thermostatic Charge. Select the charge according to the design evaporating tem-perature from the Table on page 3. Refer to Bulletin 10-9 for a complete discussion of the available Sporlan Selective Thermostatic Charges. Selection Example – Refrigerant 22 Application: medium temperature refrigeration , The Type HX Thermostatic Expansion Valve is designed for use on residential air conditioning and heat pump systems. The valve is available with an integral check valve to bypass refrigerant flow around the expansion device in reverse direction. Sporlan HX and Parker H Valves share the same internal components and feature similar thermostatic ... , To completely identify a SPORLAN thermostatic expansion valve the following information is required: To completely identify a SPORLAN thermostatic element the following information is required: 1.Type of valve (body style) 2.Refrigerant 3.External equalizer 4.Capacity in tons of refrigeration or port size 5.Type of thermostatic charge, 2 / BULLETIN 500-10-HC-CR. The selections are based on load and operating conditions provided by Heatcraft Inc. All selections are based on condensing pressures of 175 psig (R-22), 200 psig (R-404A and R-507), and 10 degree liquid subcooling. Externally equalized valves are used with coils having refrigerant distributors., PIPING - Sporlan recommends that recognized piping refer-ences, such as equipment manufacturers’ literature and the ASHRAE Handbook, be consulted for assistance with proper piping procedures. Sporlan is not responsible for system design, any damage arising from faulty system design, or for misapplication of its products. If these valves, Parker Engineering Your Success Motion Control Technology, Expansion valve, balanced port, R22 family, external equalizer, 10 tons, 5/8" ODF inlet x 7/8" ODF outlet, C charge (medium temp) Quantity. Add to Cart. Nearby Stock. ... Sporlan type O valve is a brass bar body, externally adjustable valve with ODF solder connections. The thermostatic element is replaceable and the inlet connection has a ..., The Sporlan Type SR balanced port thermostatic expansion valve has a brass bar stock body. The SR valve has standard or extended ODF Solder connections in a variety of common sizes. The valve is equipped with a serviceable inlet strainer, allowing the strainer to be cleaned or replaced without removing the valve from the system., Aug 12, 2015 · Pumper down , take the Txv apart and see whats going on inside. Theres not much to it. Slowly remove the end and you will see a big spring , then a seat , and couple pins. Just pay attention how they go , no big deal. , Problem. 16RQ. Step-by-step solution. Chapter 5, Problem 16RQ is solved. View this answer. View a sample solution. Step 1 of 2. Step 2 of 2. Back to top.