4 ton 410a piston size

Buy Goodman GSZ130481 4 Ton, 13 SEER Heat Pump, R-410A Refrigerant. Goodman technical support information, product brochures and more. ... (also called "flow rater" or "piston") in a small bag taped to the side of the heat pump. ... Suction Line Size (OD) 7/8 Inches. Product Dimensions. Width. 29.000000000 Inches. Depth. 29.000000000 …

4 ton 410a piston size. Hello, The cased "A" coil is a Model # TXCO49C4HPCO S/N Z0522LH5G made by American Standard. The 5 Ton condensor is made by Trane and it is Model # 2TTR1060A1000AA and S/N 5311T292F. I did remove the uncased coil from my air handler unit. It was in a housing that was mounted in front of the air handler.

A piston does not come with this coil; it uses the piston from your condenser. If your condenser already uses R-410a refrigerant, all you will need to do is attach the piston from the condenser to the coil. If you have any further questions, please call us and we will be happy to assist you.

Advertisement We don't often realize how much untapped energy exists all around us. The principle behind these manhole explosions is similar to how a car engine works. Imagine a ci...If you’re new to carpentry and woodworking you may be surprised to learn that lumber today is actually smaller in both width and thickness than its listed size. Expert Advice On Im... ADP - 176799976 - 4 Ton Piston Size 76 R-22/R-410A. Item: ADP176799976 . MFG: 176799976 Qty. $239.00. Diversitech 3/8" Sight Glass Sweat for Air Conditioner Condenser View Item. Add To Cart. Qty. $32.95. The Goodman GSXN3N2410 is a 2 ton cooling-only condenser unit. Providing a 13.4 SEER2 efficiency with a single stage, reciprocating compressor, the GSXN3N2410 is an inexpensive condenser to cool your home when paired with an AC coil.ADP Nominal 4 Ton, Upflow/Downflow 17.5" Wide L15 A-Coil, Aluminum, Non-Bleed TXV. Item. ... • Piston options include externally accessible body for easy piston change out and/or TXV installation. ... and E65 for size 42 models and higher. • Dual 3/4" FPT condensate drains on front-left and front-right side of drain pans.

The Guardian RAC13 - 4 Ton - Air Conditioner - 13 Nominal SEER - Single-Stage - R-410A Refrigerant RAC13J484S21 has been discontinued. Check out Expert's recommended alternatives for another top central air conditioner. ... Check the item dimensions and ensure the items will fit in your vehicle. Bring any straps and other materials that will be ...Factory R410A TXV R-22 TXV = Mainline Kit # NAEA20401TX, NAEA20501TX, NAEA20601TX, and NAEA20701TX. Consult the chart below for proper size application. – comprehensive chart on pages 2 - 4 – Mainline kit FAST part Label Convert from R-410A PISTON to R-22 TXV Model Size 18 24 30 36 42 48 60Factory R410A TXV R-22 TXV = Mainline Kit # NAEA20401TX, NAEA20501TX, NAEA20601TX, and NAEA20701TX. Consult the chart below for proper size application. – comprehensive chart on pages 2 - 4 – Mainline kit FAST part Label Convert from R-410A PISTON to R-22 TXV Model Size 18 24 30 36 42 48 60None of the systems I retrofitted employed pistons after converting to 410A. The largest system I did was 5 ton. Some utilized pistons with 22 but I put in TXVs for 410A. Some others utilized TXVs with 22 and I just changed the TXV. These were all split system but I have seen some 7.5 ton 410A RTUs with pistons. New build though, not retrofitted.3.5 Ton, 4 Ton : Product Width (in) 17.5 : Line Set Connection Type: Sweat : Liquid Line Size: 3/8 inch : Weight (lbs) 66.000000 : Refrigerant: R-410a : Suction Line Size: 7/8 inch : Warranty: 5 Year Parts, 10 Year Evaporator Coil: California Residents: see Prop 65 WARNINGI have a 1991 Rheem 2.5 ton A/C and coil. Last summer, it lost all 4 lbs of R-22. I've got several proposals for replacing it with a new compressor and coil using R-410a. All the proposals specify reuse of the existing 3/4" and 3/8" lineset. The suction line has a severe bend, almost to the point of being crimped, just before it enters the outdoor unit …

About Ferguson HVAC. Ferguson HVAC is a national distributor of residential and commercial heating and cooling equipment, parts and supplies. HVAC contractors across the country rely on us for the best unitary and ductless equipment brands and for a wide-range of HVAC products including accessories, controls, air distribution supplies, and … Factory R410A TXV R-22 TXV = Mainline Kit # NAEA20401TX, NAEA20501TX, NAEA20601TX, and NAEA20701TX. Consult the chart below for proper size application. – comprehensive chart on pages 2 - 4 – Mainline kit FAST part Label Convert from R-410A PISTON to R-22 TXV Model Size 18 24 30 36 42 48 60 Mar 19, 2017 ... Orifice along with the safety, efficiency, and service procedures involved. I compare 4 major points of difference and how they affect the ...The Goodman CAPF3636B6 evaporator coil is rated for a 3 ton output. In many system configurations, this coil may be larger in tonnage than its paired condenser. This is intentional, to maintain the overall efficiency of the entire system. Please note that in order for this coil to function, a furnace or blower and a condenser is required, all ...Liquid Line Size: 3/8 in Metering Device: Piston Motor Rating: 1/3 hp Motor Type: PSC Nominal Capacity: 3.5 ton Power Source: 208/230/1 Refrigerant Type: R-410A Series: B6BMM0 Suction Line Size: 7/8 in Supply Air Opening: 12-7/8 x 18-1/4 in. Similar Products Found in: > ELECTRIC FULL-SIZE SYSTEM

Iltexas college station calendar.

A 3.5-ton air-conditioning unit cools homes from 1,801 to 2,300 square feet, depending on location. The unit cools 1,801 to 2,100 square feet in southern states from Georgia to Cal...Size matters: Is the U.S. Navy really too small? September 9, 2015. By Zachary Cohen, CNN Updated 6:34 PM ET, Tue September 8, 2015 Sizing up the U.S. …Be the first to ask a question about this product! Product Features. Product DetailsMar 26, 2016 · Correction on reply # 15 - GSZ140481A piston size should be .078 not .080 Lessons learned the hard way.--Don't let brain think 13 SEER - R22 when working on 14 SEER -R410A -- Make sure new condenser has piston with it. Put piston chart in vehicle-carry it with me. rollandsaxton liked this post. Lennox Elite CH35, CH35-51C-2F, 4 Ton, Piston (R410A), Cased Aluminum Horizontal Evaporator Coil. Cat # : 10C38. Model/Part # : CH35-51C-2F. Replacement Available This product has been replaced by Cat# Print. Quantity: Add …

Oxbox J4AC4048A1000AA - J4AC4 4 Ton 48,000 BTU 14.3 SEER2 Single-Stage Air Conditioner - R-410A- <b>Note: As of January 1, 2023 the US Department of Energy released a new SEER2 standard that provides manufacturers guidance in measuring the efficiency of their HVAC units. <br><br> The US Department of Energy divided the …Post Likes. Originally Posted by rsmith46. Use this easy formula to charge a piston R22 system by super-heat. WB times 3 minus OD temp minus 80 times 2. WB* x 3 -OD* - 80 x 2. I don't know of a formula for figuring the target SH on 410a, since only Goodman uses pistons. Thats my problem. It is the same.If it does not match, replace indoor piston with correct piston size in table below: NOTE: Pistons shipped with outdoor units are only qualified and approved with the above listed …I am installing a new cased coil Goodman CAPF36C6 WITH A NEW FURNACE GMVC95070 TWO STAGE 95% VS W. 4 TON blower. The old condenser is staying (Armstrong SCU1036). ... Goodman told me to use Armstrong's piston size. My concern is the 3 ton 13 SEER coil is twice the size of the OEM. ... Just gonna have to … 3/8 80 (24.4) 35 (10.7) vertical or 80 (24.4) total 80 (24.4) For Heat Pump systems, the chart below shows when an application is considered Long Line. HP WITH R−410A REFRIGERANT LONG LINE DESCRIPTION ft (m) Beyond these lengths, long line accessories are required Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor FIXED ORIFICE PISTON - R22 & R410A 3.0T - .068 OPENING - B1789868.Manuals and buying guide for Comfortmaker - FEM4P3600A - Piston Air Handler R410A, 3 Ton, Copper Tube, Aluminum Fin Evaporator. Find specifications on Comfortmaker FEM4P3600A. Hotline Free: (888) 882-4424piston size dimensions shipping information cabinet width (w)” cabinet depth (d)” cabinet height (h)” shipping weight (lbs) skid r22 r410a min width max width 2 row 3 row 4 row qty de24a* 0.059 0.055 142 21 21 1/2 19 33 36 41 20 de24b* 0.059 0.055 142 21 21 1/2 19 36 39 45 20 de24c* 0.059 0.055 142 21 21 1/2 23 40 46 50 16I have a 1991 Rheem 2.5 ton A/C and coil. Last summer, it lost all 4 lbs of R-22. I've got several proposals for replacing it with a new compressor and coil using R-410a. All the proposals specify reuse of the existing 3/4" and 3/8" lineset. The suction line has a severe bend, almost to the point of being crimped, just before it enters the outdoor unit …ADP Nominal 4 Ton ... 3/4" ODF on A-Coil 18-36 size models 2. 7/8" ODF ... R-22, R-410A, AC and Heat Pump compatible with appropriate TXV or piston installed.Jul 16, 2021 · As the efficiency goes up pressure difference drops. 410 carries more BTU's /LB than 22. When you add all those up it could come out the same. In other words it takes a certain size orifice to move X lb of R-22 equal to Y BTU and that same size orifice just happens to move the right amount of R-410a because the efficiency of the system creates ... Piston Size R-22 R-410A Ton Piston Size Part # Piston Size Part # 1 41 100000035 41 100000035 1.5 53 100000036 49 100000049 2 59 100000037 53 100000036 2.5 67 100000039 59 100000037 3 73 100000041 67 100000039 3.5 80 100000044 73 100000041 4 84 100000045 76 100000042 5 93 100000047 93 100000047 ...

Page 18 14SEER R410A HP Charge Chart 4 TON(Cooling mode) Outdoor Ambient Temperature ... Matching table and Checkout Procedures 18.1 Matching table If Preinstalled Piston Condensing Unit Air Handle / A-Coil Piston Size / TXV Valve Model SEER Replace Required J4AH4P18A1A00AA 0.050/(4AYTXVH3G2436A) J4AH4E24A1A00AA …

Line Size -- Liquid (in.) R-410A BRAZED 3/4 3/8 R-410A BRAZED 3/4 3/8 R-410A BRAZED 7/8 3/8 DIMENSIONS (in.) Crated (H x W x D) ... Piston Size Piston Kit 0.052 MAYORIACHP0052B 0.058 MAYORIACHP0058B 0.063 MAYORIACHP0063B ... 0.083 MAYORIACHP0083B 0.090 MAYORIACHP0090B Tons R410A TXV Kit(If required) R22 … Some common piston sizes for R22 systems include 0.052, 0.059, and 0. 066, but it’s essential to consult your manufacturer’s specifications to determine the correct size for your particular model. 3/8 80 (24.4) 35 (10.7) vertical or 80 (24.4) total 80 (24.4) For Heat Pump systems, the chart below shows when an application is considered Long Line. HP WITH R−410A REFRIGERANT LONG LINE DESCRIPTION ft (m) Beyond these lengths, long line accessories are required Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above IndoorBales of hay vary in size from 40 to 2,000 pounds. A three-string bale weighs around 100 pounds, and there are approximately 20 three-string bales in a ton. Round bales weigh 850 t...Thanks for the offer turtle, but according to the coil piston charts by Goodman, your range is way off. The only piston noted for any of the Goodman 2.5 ton outdoor units is the .065 piston. If you are thinking that the piston numbers noted in each of the catagories such as .058 to .065 or .078 to .065 are a range, you are reading the chart wrong.Manuals and buying guide for Comfortmaker - FEM4P3600A - Piston Air Handler R410A, 3 Ton, Copper Tube, Aluminum Fin Evaporator. Find specifications on Comfortmaker FEM4P3600A. Hotline Free: (888) 882-4424The electric vehicle revolution came to the streets of Munich this week in the form of a 40-ton, all-electric truck. The electric vehicle revolution came to the streets of Munich, ...The CHX35 family of coils are designed with aluminum tube construction which provides great heat transfer and additional resistance to environmental contaminants. Durable components, such as corrosion-resistant casing and drain pans, help guard against unexpected service calls. CHX35-51/61C-6F-1 coil is built to high standards and is …4 To 5 Ton TXV Kit - R-410A Refrigerant. ( 5 Reviews) Model: Blueridge BGH4TXV03. $ 109.99. Or as low as. Buy in monthly payments with Affirm on orders over $50. Learn more. You save: 30%. Compare to: $157.92.

Will big chief return to street outlaws.

Playgd mobi golden dragon hack.

R-410A environmentally friendly refrigerant. System Size (Tons): 4 ... you need to throw out your old air conditioner that hasn’t kept you cool in ages and switch it out with the ProDirect 4 Ton 15 SEER Split System A/C Condenser from MRCOOL. ... the piston flow control device manages the speed and volume of the refrigerant as it runs to ...The Guardian RAC13 - 4 Ton - Air Conditioner - 13 Nominal SEER - Single-Stage - R-410A Refrigerant RAC13J484S21 has been discontinued. Check out Expert's recommended alternatives for another top central air conditioner. ... Check the item dimensions and ensure the items will fit in your vehicle. Bring any straps and other materials that will be [email protected]. (888) 601–0038. Follow Us. ADP 100000039 - Piston .67, 2 1/2 Ton R22, 3 Ton R410APiston Size 67. Can be used on 2 1/2 Ton R22 Coil or 3 Ton R410a Coil.Residential Fan Coil; with standard features:ENVIRONMENTALLY SOUND R-410A SYSTEMSFactory installed piston metering device with Teflon ringHigh efficiency ECM, 5-speed motorCopper tube/aluminum fin coil on standard modelsAvailable with …None of the systems I retrofitted employed pistons after converting to 410A. The largest system I did was 5 ton. Some utilized pistons with 22 but I put in TXVs for 410A. Some others utilized TXVs with 22 and I just changed the TXV. These were all split system but I have seen some 7.5 ton 410A RTUs with pistons. New build though, not retrofitted.100000042 ADP Piston - size 76 R410A (4 Ton) Abrpn: 100000042. Your No. This is non stock item. More Information. SKU. 104214. Default UOM.This manual is also suitable for: View and Download Goodman GPH 14 SEER R-410A technical manual online. GPH 14 SEER R-410A Package Heat Pump Units. GPH 14 SEER R-410A heat pump pdf manual download. Also for: Gph1424h41ab, Gph1430h41ab, Gph1436h41ab, Gph1442h41ab, Gph1448h41ab, Gph1460h41ab.I work at a University, and am fighting a reoccurring issue with a residential split system not keeping up when temps get into the mid 80's and up. Unit is a 3 ton R410 I.C.P. unit, fixed orifice. Indoor unit calls for a 070 piston. This piston in it is 067. Condenser only references TXV, doesn't specify a piston size. Subcool is approx 10, …The amount of material a dump truck holds depends on the size of the dump truck, and the type of material dictates the number of tons. For example, a cubic yard of sand weighs 2.2 ...Piston size-non tXV use Tonnage R22 (F) R410A (G) Orifice Sz PART # Orifice Sz PART # 1T 0.041 3962 N/A N/A 1.5T 0.055 3999 0.049 4006 2T 0.059 4000 0.055 3999 2.5T … CAUF4860C6 20" 28" 25" 4-5 ⅜" ⅞" .093 48 CAUF4860D6 23" 28" 25" 4-5 ⅜" ⅞" .093 39 CAUF4961C6 20" 28" 25" 4-5 ⅜" ⅞" .093 54 CAUF4961D6 23" 27" 25" 4-5 ⅜" ⅞" .093 59 * Shipped with Coil Note: For a properly matched system and piston sizing information, refer to Goodman piston kit chart of the corresponding Goodman® outdoor unit. piston kit chart 4 ppkcg-4001j february 2015 (*) signifies unit revision. (1) correct piston is supplied with the outdoor unit. (2) correct piston is supplied in the highest sales volume tested combination indoor unit. for all other indoor combinations, piston must be purchased from distributor. (3) txv must be purchased separately. ….

If you’re new to carpentry and woodworking you may be surprised to learn that lumber today is actually smaller in both width and thickness than its listed size. Expert Advice On Im...Post Likes. Originally Posted by rsmith46. Use this easy formula to charge a piston R22 system by super-heat. WB times 3 minus OD temp minus 80 times 2. WB* x 3 -OD* - 80 x 2. I don't know of a formula for figuring the target SH on 410a, since only Goodman uses pistons. Thats my problem. It is the same.ADP 100000042 - Piston .76, 4 Ton R410APiston Size 76. Can be used on 4 Ton R410a Coil.Testing Instruments. Manifolds and Gauges. ADP - 176799976 - 4 Ton Piston Size 76 R-22/R-410A. Advanced Distributor Products. Piston Size Optional TXV SEER "Preinstalled Piston" Attached Piston If Preinstalled Piston Replace Required AC M4AC3018B1000AA M4CXC024BA1CAAA C050 MAYTXVACAC1818AA 13 056 050 YES M4CXC025BB1CAAA C050 MAYTXVACAC1818AA 13 056 050, 060, 061 YES M4CXC030BB1CAAA C050 MAYTXVACAC1818AA 13 063 068, 058, 057, 064, 050, 070, 051 YES Advertisement We don't often realize how much untapped energy exists all around us. The principle behind these manhole explosions is similar to how a car engine works. Imagine a ci... assembled, piped and wired at the factory to provide a single-piece. unit for shipment and rigging. Each unit is pressurized with a holding. charge of refrigerant R-410A for storage and/or shipping. The compact design, clean styling, small footprint, and quiet operation. make these condensing units and heat pumps suitable for almost any. Capillary Tube Length (in.) 17.810 (1). Inside Diameter (in.) .095 (1). Number of Capillary Tubes. 6 (4); 3 (2); 2 (1). Orifice Diameter (in.). 4 ton 410a piston size, R-22 R-410A Florator Piston for 60 (Piston Size 93) All Air Handler Model. Cat # : 17N36. Model/Part # : 10000047. Sign in for pricing and availability. Print. Quantity: Add to Cart. Save to List., At 236,857 tons, Wonder of the Seas will be nearly 4% bigger than the current size leader in the cruise world, Royal Caribbean's 3-year-old Symphony of the Seas The first voyages o..., Line Size -- Liquid (in.) R-410A BRAZED 3/4 3/8 R-410A BRAZED 3/4 3/8 R-410A BRAZED 7/8 3/8 DIMENSIONS (in.) Crated (H x W x D) ... Piston Size Piston Kit 0.052 MAYORIACHP0052B 0.058 MAYORIACHP0058B 0.063 MAYORIACHP0063B ... 0.083 MAYORIACHP0083B 0.090 MAYORIACHP0090B Tons R410A TXV Kit(If required) R22 …, Effective 4/1/10. Subject to change without notice. R22 (F) R410A (G) Tonnage Orifice Sz PART # Orifice Sz PART # 1.5T 0.055 3999 0.049 4006 2T 0.059 4000 0.055 3999 2.5T 0.068 3987 0.059 4000 3T 0.074 4001 0.068 3987 3.5T 0.080 3990 0.074 4001 4T 0.084 3991 0.080 3990 5T 0.092 3998 0.089 3960 Table 1: Piston Size- Non TXV use , Piston 410a holooly410a goodman 4.0 ton rheem 14 seer r-410a central system ra1448aj1na, rh1p4821stanjaArmstrong em1p48bg 4 ton multiposition cased coil piston r22 or 410a. Check Details. Piston size chart 410a. Piston hvac r22 tapatalkPiston 410a holooly A cylinder/piston setup contains 1 l of saturated liquid refrigerant rHvac …, Wrong piston size for 15 year unit never ran right from the date of install www.amazon.com/shop/miheatingguyMilwaukee 2131-20 M18 ROCKET Dual Power Tower Lig..., assembled, piped and wired at the factory to provide a single-piece. unit for shipment and rigging. Each unit is pressurized with a holding. charge of refrigerant R-410A for storage and/or shipping. The compact design, clean styling, small footprint, and quiet operation. make these condensing units and heat pumps suitable for almost any. , Buy Goodman B1789857 2 Ton Orifice Kit for R-410A, 14 SEER Air Conditioner. Goodman technical support information, product brochures and more. Place Your Order by 1 pm for Same-Day Shipping, FIXED ORIFICE PISTON - R22 & R410A 3.0T - .068 OPENING - B1789868., I am installing a new cased coil Goodman CAPF36C6 WITH A NEW FURNACE GMVC95070 TWO STAGE 95% VS W. 4 TON blower. The old condenser is staying (Armstrong SCU1036). tHE OLD COIL HAS A #71 piston. The condenser calls for #68 but the specs say it's a 2 1/2 ton orifice. Considering the condenser is a 3 ton this has me a bit confused., a. Exceptions for air conditioning (cooling only) applications, 1/4" liquid line may be used in: i. 1.5 ton applications for up to 100 equivalent feet (30.5 equivalent meters) with maximum 40’ (12.2 m) vertical lift ii. 2.0 ton applications for up to 75 equivalent feet (22.9 equivalent meters) with maximum 20’ (6.1 m) vertical lift b., *Piston size needed for system combination may not be pre-installed. See Table 1 for pre-installed size. **Necessary piston size varies for this tonnage. See Table 3. Table 3. R410a piston sizes for 2.5T outdoor capacity system. Piston Unit Model* Coil Model Size (R410a) 4MXCA001AC6HCA 0.052 factory installed 4MXCB002AC6HCA 0.052 factory installed , 4 physical data unit size 024 030 036 042 048 060 nominal capacity (ton) 2 2.5 3 3.5 4 5 shipping weight (lb) (kg) 312 142 333 151 334 152 388 177 407 185 475 215 compressor type scroll refrigerant r-410a refrigerant quantitiy (lb) quantity (kg) 6.3 2.9 9.8 3.1 6.8 3.1 7.7 3.5 9.0 4.1 12.0 5.4 outdoor metering device txv piston txv piston ..., Aug 4, 2020 ... Welcome to HVAC with John Israel YouTube Channel. On this channel I Bring you along on HVAC Service calls, HVAC Installs, HVAC Maintenance ..., If it does not match, replace indoor piston with correct piston size in table below: NOTE: Pistons shipped with outdoor units are only qualified and approved with the above listed fan coils. PHYSICAL DATA (Copper Coil Models) UNIT SIZE 18(A,G)KH 24(A,G)KH 30(A,G)KH 36(A,G)KH 42(A,G)KH 48(A,G)KH 60(A,G)KH Compressor Type Scroll REFRIGERANT R-410A, Piston size-non tXV use Tonnage R22 (F) R410A (G) Orifice Sz PART # Orifice Sz PART # 1T 0.041 3962 N/A N/A 1.5T 0.055 3999 0.049 4006 2T 0.059 4000 0.055 3999, Dec 1, 2017 ... The system in the video contains R-410A ... ton systems. The Carrier system's data plate ... HVAC 089 fixed orifice piston closer look inside., Piston, 5 Ton, R22 And R410A, .093. Rheem warranty processing will not be available April 19th 9 PM EST – 20th 5 PM EST due to scheduled maintenance., I have a 1991 Rheem 2.5 ton A/C and coil. Last summer, it lost all 4 lbs of R-22. I've got several proposals for replacing it with a new compressor and coil using R-410a. All the proposals specify reuse of the existing 3/4" and 3/8" lineset. The suction line has a severe bend, almost to the point of being crimped, just before it enters the outdoor unit …, Goodman-Amana B1789859 - Restrictor Orifice, B1789859- 13 SEER fixed orifice piston kit. Orifice opening of .059 for 2.0 ton R-22 and 2.5 ton R-410A units (GSX130301AB) Free shipping on orders over $99, Product Description. Features. 10 year warranty on parts & compressor High efficiency scroll compressor. Direct drive multi-speed PSC indoor motor. All aluminum evaporator coil Designed for upflow, downflow, horizontal left and horizontal right installations. Condenser pre-charged with R-410A refrigerant. Insulated air handler cabinet., Wrong piston size for 15 year unit never ran right from the date of install www.amazon.com/shop/miheatingguyMilwaukee 2131-20 M18 ROCKET Dual Power Tower Lig..., Post Likes. Originally Posted by rsmith46. Use this easy formula to charge a piston R22 system by super-heat. WB times 3 minus OD temp minus 80 times 2. WB* x 3 -OD* - 80 x 2. I don't know of a formula for figuring the target SH on 410a, since only Goodman uses pistons. Thats my problem. It is the same., PISTON KIT 2.5 TON R410A FOR C33-30B-2F. Specifications . Minimum Purchase: 1 unit: Manufacturer Part Number: ... Universal 4 Ton TXV R-410A $159.62. $236.51 Save $76.89. Add to Cart The item has been added. Lennox. 10W86 - 100484-28 Kit-RFC Piston (.080) 3.5 ton $62.32 Add to Cart The ..., 4 to 5 ton evaporator coil. Installable in the horizontal configuration. Usable with either a heat pump or an AC-only condenser. Works with R410A or R22 refrigerant. Low air leakage. Check flowrater expansion device for use in any application. 4 to 5 Tons. At an output of 4 to 5 tons, the Goodman CHPF4860D6 evaporator coil is ready for almost ..., Sx.e Vendor: ADVANCED DISTRIBUTOR PRODUCTS. Advanced Distributor Products #53, Florator Piston for 1.5 Ton R-22 and 2 Ton R-410A Air Handler Evaporator Coil. Specifications. Size: #53. Used On Item: 1.5 Ton R22, 2 Ton R410A Air Handler Evaporator Coil. Used On Model/Brand: 18, 24. QTY., 3. Remove the piston from the mechanical fitting in liquid line. Remove and discard the O-ring. NOTE: Remove the piston. 4. Install new O-ring on fitting. O-ring is supplied in kit. 5. Using a back-up wrench, reattach the fittings. Tighten until bodies “bottom” or a definite resistance is felt. The valve will only fit in one direction of flow., I am installing a new cased coil Goodman CAPF36C6 WITH A NEW FURNACE GMVC95070 TWO STAGE 95% VS W. 4 TON blower. The old condenser is staying (Armstrong SCU1036). tHE OLD COIL HAS A #71 piston. The condenser calls for #68 but the specs say it's a 2 1/2 ton orifice. Considering the condenser is a 3 ton this has me a bit confused., If it does not match, replace indoor piston with correct piston size in table below: NOTE: Pistons shipped with outdoor units are only qualified and approved with the above listed fan coils. PHYSICAL DATA (Copper Coil Models) UNIT SIZE SERIES 18BNG-E 24BNG-F 30BNG-D 36BNG-D 420NG-A 48BNG-E 600NG-C Compressor Type Scroll REFRIGERANT Puron (R-410A) , Qty. $239.00. Diversitech 3/8" Sight Glass Sweat for Air Conditioner Condenser View Item. Add To Cart. Qty. $32.95. The Goodman GSXN3N2410 is a 2 ton cooling-only condenser unit. Providing a 13.4 SEER2 efficiency with a single stage, reciprocating compressor, the GSXN3N2410 is an inexpensive condenser to cool your home when paired with an AC coil., Manuals and buying guide for Comfortmaker - FEM4P3600A - Piston Air Handler R410A, 3 Ton, Copper Tube, Aluminum Fin Evaporator. Find specifications on Comfortmaker FEM4P3600A. Hotline Free: (888) 882-4424 , Brand New HEIL 2.5 Ton R-410A Piston Air Handler Multi-Position Aluminum 208/230/1 Model# FEM4P3000AL #BSP1 ... Refrigerant Type R-410A Liquid Line Size 3/8 in Suction Line Size 3/4 in Filter Size 16-3/8 x 21-1/2 in Motor Type ECM Motor Rating 1/3 hp Dimensions 49-5/8 in H x 17-5/8 in W x 22-1/16 in D ..., 3/4" FEMALE NPT PRIMARY & SECONDARY DRAIN CONNECTIONS (IMPORTANT: HAND TIGHTEN) SUCTION CONNECTION LIQUID CONNECTION CAPF3636C6 PISTON SECTION XSEC0002-XSEC0002 Specifications Model Cabinet Dimensions Nominal Tons Connection Piston Size* (in.) Ship Weight W D H Liquid Suction (lbs) CAPF3137B6 17½" 21" 30" 2½-3 ⅜" ¾" .071 53